This page is part of the FHIR Specification (v5.0.0-snapshot1: Release 5 Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
| Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw Turtle (+ also see Turtle/RDF Format Specification)
IV Chemotherapy Example - Manufactured Product - Adcetris
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Medication/med0306> a fhir:Medication;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "med0306"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource "med0306" </p></div><p><b>code</b>: Adcetris <span> (<a>National drug codes</a>#51144-050-01)</span></p><p><b>marketingAuthorizationHolder</b>: <a> </a></p><blockquote><div><p>Resource "mmanu" </p></div><p><b>name</b>: Medication Manufacturer</p></blockquote><p><b>doseForm</b>: Lyophilized powder for injectable solution (qualifier value) <span> (<a>SNOMED CT</a>#421637006)</span></p><h3>Batches</h3><table><tr><td>-</td><td><b>LotNumber</b></td><td><b>ExpirationDate</b></td></tr><tr><td>*</td><td>12345</td><td>2019-10-31</td></tr></table></div>"
];
fhir:DomainResource.contained [
a fhir:Organization;
fhir:index 0;
fhir:Resource.id [ fhir:value "mmanu" ];
fhir:Organization.name [ fhir:value "Medication Manufacturer" ]
];
fhir:Medication.code [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
fhir:Coding.code [ fhir:value "51144-050-01" ];
fhir:Coding.display [ fhir:value "Adcetris" ]
]
];
fhir:Medication.marketingAuthorizationHolder [
fhir:Reference.reference [ fhir:value "#mmanu" ]
];
fhir:Medication.doseForm [
fhir:CodeableConcept.coding [
fhir:index 0;
a sct:421637006;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "421637006" ];
fhir:Coding.display [ fhir:value "Lyophilized powder for injectable solution (qualifier value) " ]
]
];
fhir:Medication.batch [
fhir:Medication.batch.lotNumber [ fhir:value "12345" ];
fhir:Medication.batch.expirationDate [ fhir:value "2019-10-31"^^xsd:date ]
] .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Medication/med0306.ttl> a owl:Ontology;
owl:imports fhir:fhir.ttl;
owl:versionIRI <http://build.fhir.org/Medication/med0306.ttl> .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.