This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw XML (canonical form + also see XML Format Specification)
example-pacemaker (id = "example-pacemaker")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="example-pacemaker"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-pacemaker"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "example-pacemaker" </p> </div> <p> <b> identifier</b> : id: 1234-5678-90AB-CDEF</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> lotNumber</b> : 1234-5678</p> <h3> DeviceNames</h3> <table class="grid"><tr> <td> -</td> <td> <b> Name</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> PM/Octane 2014</td> <td> user-friendly-name</td> </tr> </table> <p> <b> type</b> : Performance pace maker for high octane patients <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (devices#octane2014)</span> </p> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> attached <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (device-associationstatus#attached)</span> </td> <td> <a href="patient-example.html">Patient/example</a> "Peter CHALMERS"</td> </tr> </table> <p> <b> contact</b> : ph: ext 4352</p> </div> </text> <identifier> <system value="http://acme.com/devices/pacemakers/octane/serial"/> <value value="1234-5678-90AB-CDEF"/> </identifier> <manufacturer value="Acme Devices, Inc"/> <lotNumber value="1234-5678"/> <deviceName> <name value="PM/Octane 2014"/> <type value="user-friendly-name"/> </deviceName> <type> <coding> <system value="http://acme.com/devices"/> <code value="octane2014"/> <display value="Performance pace maker for high octane patients"/> </coding> </type> <association> <status> <coding> <system value="http://terminology.hl7.org/CodeSystem/device-associationstatus"/> <code value="attached"/> </coding> </status> <humanSubject> <reference value="Patient/example"/> </humanSubject> </association> <contact> <system value="phone"/> <value value="ext 4352"/> </contact> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.