This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw Turtle (+ also see Turtle/RDF Format Specification)
example-pacemaker
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- [a fhir:Device; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "example-pacemaker"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-pacemaker\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example-pacemaker" </p></div><p><b>identifier</b>: id: 1234-5678-90AB-CDEF</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>lotNumber</b>: 1234-5678</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>PM/Octane 2014</td><td>user-friendly-name</td></tr></table><p><b>type</b>: Performance pace maker for high octane patients <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (devices#octane2014)</span></p><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>attached <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (device-associationstatus#attached)</span></td><td><a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</td></tr></table><p><b>contact</b>: ph: ext 4352</p></div>" ]; fhir:Device.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "http://acme.com/devices/pacemakers/octane/serial" ]; fhir:Identifier.value [ fhir:value "1234-5678-90AB-CDEF" ] ]; fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"]; fhir:Device.lotNumber [ fhir:value "1234-5678"]; fhir:Device.deviceName [ fhir:index 0; fhir:Device.deviceName.name [ fhir:value "PM/Octane 2014" ]; fhir:Device.deviceName.type [ fhir:value "user-friendly-name" ] ]; fhir:Device.type [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://acme.com/devices" ]; fhir:Coding.code [ fhir:value "octane2014" ]; fhir:Coding.display [ fhir:value "Performance pace maker for high octane patients" ] ] ]; fhir:Device.association [ fhir:index 0; fhir:Device.association.status [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/device-associationstatus" ]; fhir:Coding.code [ fhir:value "attached" ] ] ]; fhir:Device.association.humanSubject [ fhir:Reference.reference [ fhir:value "Patient/example" ] ] ]; fhir:Device.contact [ fhir:index 0; fhir:ContactPoint.system [ fhir:value "phone" ]; fhir:ContactPoint.value [ fhir:value "ext 4352" ] ]] . # - ontology header ------------------------------------------------------------ [a owl:Ontology; owl:imports fhir:fhir.ttl] . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.