This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Request for Subcutaneous injection - Insulin - Lantus - completed, with reason code and dispense request (id = "medrx0320")
<?xml version="1.0" encoding="UTF-8"?> <MedicationRequest xmlns="http://hl7.org/fhir"> <id value="medrx0320"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <div> <p> Resource "medrx0320" </p> </div> <p> <b> identifier</b> : id: 12345689 (OFFICIAL)</p> <p> <b> status</b> : completed</p> <p> <b> intent</b> : order</p> <p> <b> medication</b> : Lantus 100 unit/ml injectable solution <span> (<a> RxNorm</a> #285018)</span> </p> <p> <b> subject</b> : <a> Patient/pat1: Donald Duck</a> "Duck DONALD"</p> <p> <b> authoredOn</b> : 2015-01-15</p> <p> <b> requester</b> : <a> Practitioner/f007: Patrick Pump</a> "Simone HEPS"</p> <p> <b> reasonCode</b> : On subcutaneous insulin for diabetes mellitus (finding) <span> (<a> SNOMED CT</a> #473189005)</span> </p> <blockquote> <p> <b> dispenseRequest</b> </p> <p> <b> validityPeriod</b> : 2015-01-15 --> 2016-01-15</p> <p> <b> numberOfRepeatsAllowed</b> : 6</p> <p> <b> quantity</b> : 10 mL<span> (Details: UCUM code mL = 'mL')</span> </p> </blockquote> </div> </text> <identifier> <use value="official"/> <system value="http://www.bmc.nl/portal/prescriptions"/> <value value="12345689"/> </identifier> <status value="completed"/> <intent value="order"/> <medicationCodeableConcept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="285018"/> <display value="Lantus 100 unit/ml injectable solution"/> </coding> </medicationCodeableConcept> <subject> <!-- Linked to the resource patient who needs the medication --> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> <authoredOn value="2015-01-15"/> <requester> <reference value="Practitioner/f007"/> <display value="Patrick Pump"/> </requester> <reasonCode> <coding> <system value="http://snomed.info/sct"/> <code value="473189005"/> <display value="On subcutaneous insulin for diabetes mellitus (finding)"/> </coding> </reasonCode> <dosageInstruction> <sequence value="1"/> <text value="20 Units SC three times daily"/> <timing> <repeat> <frequency value="3"/> <period value="1"/> <periodUnit value="d"/> </repeat> </timing> <route> <coding> <system value="http://snomed.info/sct"/> <code value="263887005"/> <display value="Subcutaneous (qualifier value)"/> </coding> </route> <doseAndRate> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/dose-rate-type"/> <code value="ordered"/> <display value="Ordered"/> </coding> </type> <doseQuantity> <value value="20"/> <unit value="U"/> <system value="http://unitsofmeasure.org"/> <code value="U"/> </doseQuantity> </doseAndRate> </dosageInstruction> <dispenseRequest> <validityPeriod> <start value="2015-01-15"/> <end value="2016-01-15"/> </validityPeriod> <numberOfRepeatsAllowed value="6"/> <quantity> <value value="10"/> <unit value="mL"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </quantity> <expectedSupplyDuration> <value value="30"/> <unit value="days"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </expectedSupplyDuration> </dispenseRequest> </MedicationRequest>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.