Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Orders and Observations icon Work GroupMaturity Level: N/AStandards Status: InformativeSecurity Category: Patient Compartments: Device, Patient, Practitioner

Search Parameter Registry for the specimen resource

Search parameter list for this resource. The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.

http://hl7.org/fhir/SearchParameter/Specimen-accession

Parameter accession:token

The accession number associated with the specimen

ResourceSpecimen
ExpressionSpecimen.accessionIdentifier
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-bodysite

Parameter bodysite:reference

Reference to a resource (by instance)

ResourceSpecimen
ExpressionSpecimen.collection.bodySite.reference
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-collected

Parameter collected:date

The date the specimen was collected

ResourceSpecimen
ExpressionSpecimen.collection.collected
MultiplesThe parameter cannot repeat or have multiple values
ComparatorsAllowed: eq, ne, gt, ge, lt, le, sa, eb, ap
 
http://hl7.org/fhir/SearchParameter/Specimen-collector

Parameter collector:reference

Who collected the specimen

ResourceSpecimen
ExpressionSpecimen.collection.collector
Target ResourcesPractitioner, Patient, PractitionerRole, RelatedPerson
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-container-device

Parameter container-device:reference

The unique identifier associated with the specimen container

ResourceSpecimen
ExpressionSpecimen.container.device.where(resolve() is Device)
Target ResourcesDevice
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-identifier

Parameter identifier:token

The unique identifier associated with the specimen

ResourceSpecimen
ExpressionSpecimen.identifier
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-parent

Parameter parent:reference

The parent of the specimen

ResourceSpecimen
ExpressionSpecimen.parent
Target ResourcesSpecimen
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-patient

Parameter patient:reference

The patient the specimen comes from

ResourceSpecimen
ExpressionSpecimen.subject.where(resolve() is Patient)
Target ResourcesPatient
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-procedure

Parameter procedure:reference

The procedure that collected the specimen

ResourceSpecimen
ExpressionSpecimen.collection.procedure
Target ResourcesProcedure
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-status

Parameter status:token

available | unavailable | unsatisfactory | entered-in-error

ResourceSpecimen
ExpressionSpecimen.status
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-subject

Parameter subject:reference

The subject of the specimen

ResourceSpecimen
ExpressionSpecimen.subject
Target ResourcesGroup, BiologicallyDerivedProduct, Device, Patient, Substance, Location
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/Specimen-type

Parameter type:token

The specimen type

ResourceSpecimen
ExpressionSpecimen.type
MultiplesThe parameter cannot repeat or have multiple values