Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Example Device/example-udi2 (Turtle)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw Turtle (+ also see Turtle/RDF Format Specification)

example-udi2

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

[a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "example-udi2"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi2\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;example-udi2&quot; </p></div><p><b>identifier</b>: A99971312345600</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td></tr><tr><td>*</td><td>A9999XYZ100T0474</td><td><a href=\"http://hl7.org/fhir/NamingSystem/iccbba-other\">http://hl7.org/fhir/NamingSystem/iccbba-other</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td></tr></table><p><b>status</b>: inactive</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>manufactureDate</b>: 2013-02-01</p><p><b>expirationDate</b>: <span title=\" 	013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number) \">2014-02-01</span></p><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>attached <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (device-associationstatus#attached)</span></td><td><a href=\"patient-example.html\">Patient/example</a> &quot;Peter CHALMERS&quot;</td></tr></table></div>"
  ];
  fhir:Device.identifier [
     fhir:index 0;
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-din" ]
       ]
     ];
     fhir:Identifier.value [ fhir:value "A99971312345600" ]
  ];
  fhir:Device.udiCarrier [
     fhir:index 0;
     fhir:Device.udiCarrier.deviceIdentifier [ fhir:value "A9999XYZ100T0474" ];
     fhir:Device.udiCarrier.issuer [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-other" ];
     fhir:Device.udiCarrier.jurisdiction [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ]
  ];
  fhir:Device.status [ fhir:value "inactive"];
  fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"];
  fhir:Device.manufactureDate [ fhir:value "2013-02-01"^^xsd:date];
  fhir:Device.expirationDate [ fhir:value "2014-02-01"^^xsd:date];
  fhir:Device.association [
     fhir:index 0;
     fhir:Device.association.status [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/device-associationstatus" ];
         fhir:Coding.code [ fhir:value "attached" ]
       ]
     ];
     fhir:Device.association.humanSubject [
       fhir:Reference.reference [ fhir:value "Patient/example" ]
     ]
  ]] .

# - ontology header ------------------------------------------------------------

[a owl:Ontology;
  owl:imports fhir:fhir.ttl] .

# -------------------------------------------------------------------------------------