Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example Device/RocheGlucoseMonitor (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

RocheGlucoseMonitor (id = "RocheGlucoseMonitor")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">
<id value="RocheGlucoseMonitor"/>  
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="RocheGlucoseMonitor"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;RocheGlucoseMonitor&quot; </p> </div> <p> <b> identifier</b> : System Identifier: 00-60-19-00-01-0E-92-34, Bluetooth Address: F4-5E-AB-A8-08-32</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 26868744401925</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1-di">http://hl7.org/fhir/NamingSystem/gs1-di</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> (01)26868744401925(21)92300365108</td> <td> unknown</td> </tr> </table> <p> <b> manufacturer</b> : Roche</p> <p> <b> serialNumber</b> : 92300365108</p> <h3> DeviceNames</h3> <table class="grid"><tr> <td> -</td> <td> <b> Name</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> meter+00365108</td> <td> user-friendly-name</td> </tr> </table> <p> <b> modelNumber</b> : 923</p> <p> <b> type</b> : MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span> </p> <h3> Versions</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> Value</b> </td> </tr> <tr> <td> *</td> <td> MDC_ID_PROD_SPEC_FW: Firmware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531976)</span> </td> <td> v1.8.3</td> </tr> </table> <h3> Specializations</h3> <table class="grid"><tr> <td> -</td> <td> <b> SystemType</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td> *</td> <td> MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Meter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528401)</span> </td> <td> 2</td> </tr> </table> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #68220)</span> </p> <p> <b> value</b> : MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532224)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-real-time-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.0)</span> </p> <p> <b> value</b> : real time clock supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> </div> </text> <identifier> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> 
        <code value="SYSID"/> 
        <display value="System Identifier"/> 
      </coding> 
    </type> 
    <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> 
    <value value="00-60-19-00-01-0E-92-34"/> 
  </identifier> 
  <identifier> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> 
        <code value="BTMAC"/> 
        <display value="Bluetooth Address"/> 
      </coding> 
    </type> 
    <system value="http://hl7.org/fhir/sid/eui-48"/> 
    <value value="F4-5E-AB-A8-08-32"/> 
  </identifier> 
  <udiCarrier> 
    <deviceIdentifier value="26868744401925"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierHRF value="(01)26868744401925(21)92300365108"/> 
    <entryType value="unknown"/> 
  </udiCarrier> 
  <manufacturer value="Roche"/> 
  <serialNumber value="92300365108"/> 
  <deviceName> 
    <name value="meter+00365108"/> 
    <type value="user-friendly-name"/> 
  </deviceName> 
  <modelNumber value="923"/> 
  <type> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="65573"/> 
      <display value="MDC_MOC_VMS_MDS_SIMP"/> 
    </coding> 
    <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> 
  </type> 
  <version> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="531976"/> 
      </coding> 
      <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/> 
    </type> 
    <value value="v1.8.3"/> 
  </version> 
  <specialization> 
    <systemType> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="528401"/> 
      </coding> 
      <text value="MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Meter"/> 
    </systemType> 
    <version value="2"/> 
  </specialization> 
  <property> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="68220"/> 
      </coding> 
      <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="532224"/> 
      </coding> 
      <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> 
    </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> 
        <code value="68219.0"/> 
      </coding> 
      <text value="mds-time-capab-real-time-clock"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> 
        <code value="Y"/> 
      </coding> 
      <text value="real time clock supported"/> 
    </valueCodeableConcept> 
  </property> 
  </Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.