This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw JSON (canonical form + also see JSON Format Specification)
RocheGlucoseMonitor
{ "resourceType": "Device", "id": "RocheGlucoseMonitor", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"RocheGlucoseMonitor\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "RocheGlucoseMonitor" </p></div><p><b>identifier</b>: System Identifier: 00-60-19-00-01-0E-92-34, Bluetooth Address: F4-5E-AB-A8-08-32</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>26868744401925</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)26868744401925(21)92300365108</td><td>unknown</td></tr></table><p><b>manufacturer</b>: Roche</p><p><b>serialNumber</b>: 92300365108</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>meter+00365108</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: 923</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><h3>Versions</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td>*</td><td>MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></td><td>v1.8.3</td></tr></table><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Meter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528401)</span></td><td>2</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>" }, "identifier": [ { "type": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code": "SYSID", "display": "System Identifier" } ] }, "system": "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680", "value": "00-60-19-00-01-0E-92-34" }, { "type": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code": "BTMAC", "display": "Bluetooth Address" } ] }, "system": "http://hl7.org/fhir/sid/eui-48", "value": "F4-5E-AB-A8-08-32" } ], "udiCarrier": [ { "deviceIdentifier": "26868744401925", "issuer": "http://hl7.org/fhir/NamingSystem/gs1-di", "jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi", "carrierHRF": "(01)26868744401925(21)92300365108", "entryType": "unknown" } ], "manufacturer": "Roche", "serialNumber": "92300365108", "deviceName": [ { "name": "meter+00365108", "type": "user-friendly-name" } ], "modelNumber": "923", "type": [ { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "65573", "display": "MDC_MOC_VMS_MDS_SIMP" } ], "text": "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" } ], "version": [ { "type": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "531976" } ], "text": "MDC_ID_PROD_SPEC_FW: Firmware revision" }, "value": "v1.8.3" } ], "specialization": [ { "systemType": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "528401" } ], "text": "MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Meter" }, "version": "2" } ], "property": [ { "type": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "68220" } ], "text": "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" }, "valueCodeableConcept": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "532224" } ], "text": "MDC_TIME_SYNC_NONE: No time synchronization" } }, { "type": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code": "68219.0" } ], "text": "mds-time-capab-real-time-clock" }, "valueCodeableConcept": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v2-0136", "code": "Y" } ], "text": "real time clock supported" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 Ballot hl7.fhir.core#5.0.0-ballot generated on Sat, Sep 10, 2022 05:02+1000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change