This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Serum Sample (id = "sst")
<?xml version="1.0" encoding="UTF-8"?> <Specimen xmlns="http://hl7.org/fhir"> <id value="sst"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : sst</p> <p> <b> accessionIdentifier</b> : id: 20150816-00124</p> <p> <b> type</b> : <span> Serum sample</span> </p> <p> <b> subject</b> : <a> Generated Summary: id: pat2; Medical record number: 123456 (USUAL); active; Duck D Donald (OFFICIAL); gender: other; </a> </p> <p> <b> request</b> : <a> Generated Summary: id: ft4; status: active; intent: reflex-order; <span> Free T4</span> ; occurrence: 27/08/2015 12:33:27 PM</a> </p> <h3> Collections</h3> <table> <tr> <td> -</td> <td> <b> Collector</b> </td> <td> <b> Collected[x]</b> </td> </tr> <tr> <td> *</td> <td> <a> Generated Summary: id: f202; UZI-nummer: 12345678902 (OFFICIAL), BIG-nummer: 12345678902 (OFFICIAL); active; Luigi Maas(OFFICIAL); ph: +31715269111(WORK); gender: male; birthDate: 1960-06-12</a> </td> <td> 16/08/2015 4:40:17 PM</td> </tr> </table> <h3> Containers</h3> <table> <tr> <td> -</td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> <span> Serum Separator Tube</span> </td> </tr> </table> </div> </text> <accessionIdentifier> <system value="http://acme.com/labs/accession-ids"/> <value value="20150816-00124"/> </accessionIdentifier> <type> <coding> <system value="http://snomed.info/sct"/> <code value="119364003"/> <display value="Serum sample"/> </coding> </type> <subject> <reference value="Patient/pat2"/> </subject> <request> <reference value="ServiceRequest/ft4"/> </request> <collection> <collector> <reference value="Practitioner/f202"/> </collector> <collectedDateTime value="2015-08-16T06:40:17Z"/> </collection> <container> <type> <coding> <system value="http://acme.com/labs"/> <code value="SST"/> <display value="Serum Separator Tube"/> </coding> </type> </container> </Specimen>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.