Release 4B

This page is part of the FHIR Specification (v4.3.0: R4B - STU). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Specimen-example-serum.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Patient, Practitioner

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Serum Sample (id = "sst")

<?xml version="1.0" encoding="UTF-8"?>

<Specimen xmlns="http://hl7.org/fhir">
  <id value="sst"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px
       solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource &quot;sst&quot; </p> </div> <p> <b> accessionIdentifier</b> : id: 20150816-00124</p> <p> <b> type</b> : Serum sample <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #119364003)</span> </p> <p> <b> subject</b> : <a href="patient-pat2.html">Patient/pat2</a>  &quot;Duck DONALD&quot;</p> <p> <b> request</b> : <a href="servicerequest-ft4.html">ServiceRequest/ft4</a> </p> <h3> Collections</h3> <table class="grid"><tr> <td> -</td> <td> <b> Collector</b> </td> <td> <b> Collected[x]</b> </td> </tr> <tr> <td> *</td> <td> <a href="practitioner-f202.html">Practitioner/f202</a>  &quot;Luigi Maas&quot;</td> <td> 2015-08-16T06:40:17Z</td> </tr> </table> <h3> Containers</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> Serum Separator Tube <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (labs#SST)</span> </td> </tr> </table> </div> </text> <accessionIdentifier> 
    <system value="http://acme.com/labs/accession-ids"/> 
    <value value="20150816-00124"/> 
  </accessionIdentifier> 
  <type> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="119364003"/> 
      <display value="Serum sample"/> 
    </coding> 
  </type> 
  <subject> 
    <reference value="Patient/pat2"/> 
  </subject> 
  <request> 
    <reference value="ServiceRequest/ft4"/> 
  </request> 
  <collection> 
    <collector> 
      <reference value="Practitioner/f202"/> 
    </collector> 
    <collectedDateTime value="2015-08-16T06:40:17Z"/> 
  </collection> 
  <container> 
    <type> 
      <coding> 
        <system value="http://acme.com/labs"/> 
        <code value="SST"/> 
        <display value="Serum Separator Tube"/> 
      </coding> 
    </type> 
  </container> 
</Specimen> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.