This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Patient Care Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Real-world procedure example (id = "f001")
<?xml version="1.0" encoding="UTF-8"?> <Procedure xmlns="http://hl7.org/fhir"> <id value="f001"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : f001</p> <p> <b> status</b> : completed</p> <p> <b> code</b> : <span> Heart valve replacement</span> </p> <p> <b> subject</b> : <a> P. van de Heuvel. Generated Summary: id: f001; id: 738472983 (USUAL), id: ?ngen-9? (USUAL); active; Pieter van de Heuvel ; ph: 0648352638(MOBILE), p.heuvel@gmail.com(HOME); gender: male; birthDate: 1944-11-17; <span> Getrouwd</span> ; multipleBirth</a> </p> <p> <b> encounter</b> : <a> Generated Summary: id: f001; id: v1451 (OFFICIAL); status: completed; <span> ambulatory</span> ; <span> Patient-initiated encounter</span> ; <span> Non-urgent cardiological admission</span> ; 140 min; <span> Heart valve replacement</span> </a> </p> <p> <b> occurrence</b> : 2011-06-26 --> 2011-06-27</p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Function</b> </td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <span> Care role</span> </td> <td> <a> P. Voigt. Generated Summary: id: f002; id: 730291637 (OFFICIAL), id: 174BIP3JH438 (USUAL); Pieter Voigt (OFFICIAL); ph: 0205569336(WORK), p.voigt@bmc.nl(WORK), fax: 0205669382(WORK); gender: male; birthDate: 1979-04-29</a> </td> </tr> </table> <p> <b> reason</b> : </p> <p> <b> bodySite</b> : <span> Heart valve structure</span> </p> <p> <b> outcome</b> : <span> improved blood circulation</span> </p> <p> <b> report</b> : <a> Lab results blood test. Generated Summary: id: f001</a> </p> <p> <b> followUp</b> : <span> described in care plan</span> </p> </div> </text> <status value="completed"/> <code> <coding> <system value="http://snomed.info/sct"/> <code value="34068001"/> <display value="Heart valve replacement"/> </coding> </code> <subject> <reference value="Patient/f001"/> <display value="P. van de Heuvel"/> </subject> <encounter> <reference value="Encounter/f001"/> </encounter> <occurrencePeriod> <start value="2011-06-26"/> <end value="2011-06-27"/> </occurrencePeriod> <performer> <function> <coding> <system value="urn:oid:2.16.840.1.113883.2.4.15.111"/> <!-- "AssignedRoleType" coding system --> <code value="01.000"/> <display value="Arts"/> </coding> <text value="Care role"/> </function> <actor> <reference value="Practitioner/f002"/> <display value="P. Voigt"/> </actor> </performer> <reason> <concept> <text value="Heart valve disorder"/> </concept> </reason> <bodySite> <coding> <system value="http://snomed.info/sct"/> <code value="17401000"/> <display value="Heart valve structure"/> </coding> </bodySite> <outcome> <text value="improved blood circulation"/> </outcome> <report> <reference value="DiagnosticReport/f001"/> <display value="Lab results blood test"/> </report> <followUp> <text value="described in care plan"/> </followUp> </Procedure>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.