This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Real-world patient example (id = "f001")
<?xml version="1.0" encoding="UTF-8"?> <Bundle xmlns="http://hl7.org/fhir"> <id value="f001"/> <type value="collection"/> <entry> <fullUrl value="https://example.com/base/DiagnosticReport/f001"/> <resource> <DiagnosticReport> <!-- ISO 8601 --><!-- OID: 2.16.840.1.113883.4.642.1.7 --><id value="f001"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><h2> <span> Complete blood count (hemogram) panel - Blood by Automated count</span> (<span> Haematology test</span> ) </h2> <table> <tr> <td> Subject</td> <td> <b> Pieter van de Heuvel </b> 1944-11-17 ( id: 738472983 (USUAL))</td> </tr> <tr> <td> Reported</td> <td> 16/05/2013 4:32:52 AM</td> </tr> <tr> <td> Identifier:</td> <td> id: nr1239044 (OFFICIAL)</td> </tr> </table> <p> <b> Report Details</b> </p> <table> <tr> <td> <b> Code</b> </td> <td> <b> Value</b> </td> <td> <b> Reference Range</b> </td> <td> <b> Flags</b> </td> <td> <b> When For</b> </td> <td> <b> Reported</b> </td> </tr> <tr> <td> <a> <span> Glucose [Moles/volume] in Blood</span> </a> </td> <td> 6.3 mmol/l</td> <td> 3.1 mmol/l - 6.2 mmol/l</td> <td> <span> High</span> </td> <td> 02/04/2013 7:30:10 PM --> (ongoing)</td> <td> 04/04/2013 1:30:10 AM</td> </tr> <tr> <td> <a> <span> Base excess in Blood by calculation</span> </a> </td> <td> 12.6 mmol/l</td> <td> 7.1 mmol/l - 11.2 mmol/l</td> <td> <span> High</span> </td> <td> 02/04/2013 8:30:10 PM --> 05/04/2013 8:30:10 PM</td> <td> 04/04/2013 1:30:10 AM</td> </tr> <tr> <td> <a> <span> Carbon dioxide in blood</span> </a> </td> <td> 6.2 kPa</td> <td> 4.8 kPa - 6.0 kPa</td> <td> <span> High</span> </td> <td> 02/04/2013 8:30:10 PM --> 05/04/2013 8:30:10 PM</td> <td> 04/04/2013 1:30:10 AM</td> </tr> <tr> <td> <a> <span> Erythrocytes [#/volume] in Blood by Automated count</span> </a> </td> <td> 4.12 10^12/L</td> <td> 12-14 y Male: 4.4 - 5.2 x 10^12/L ; 12-14 y Female: 4.2 - 4.8 x 10^12/L ; 15-17 y Male: 4.6 - 5.4 x 10^12/L ; 15-17 y Female: 4.2 - 4.8 x 10^12/L ; 18-64 y Male: 4.6 - 5.4 x 10^12/L ; 18-64 y Female: 4.0 - 4.8 x 10^12/L ; 65-74 y Male: 4.3 - 5.3 x 10^12/L ; 65-74 y Female: 4.1 - 4.9 x 10^12/L </td> <td> <span> Low</span> </td> <td> 02/04/2013 8:30:10 PM --> 05/04/2013 8:30:10 PM</td> <td> 04/04/2013 1:30:10 AM</td> </tr> <tr> <td> <a> <span> Hemoglobin [Mass/volume] in Blood</span> </a> </td> <td> 7.2 g/dl</td> <td> 7.5 g/dl - 10 g/dl</td> <td> <span> Low</span> </td> <td> 05/04/2013 8:30:10 PM --> 05/04/2013 8:30:10 PM</td> <td> 06/04/2013 1:30:10 AM</td> </tr> </table> <p> Core lab</p> </div> </text> <identifier> <use value="official"/> <system value="http://www.bmc.nl/zorgportal/identifiers/reports"/> <value value="nr1239044"/> </identifier> <basedOn> <reference value="ServiceRequest/req"/> </basedOn> <status value="final"/> <category> <coding> <system value="http://snomed.info/sct"/> <code value="252275004"/> <display value="Haematology test"/> </coding> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0074"/> <code value="HM"/> </coding> </category> <code> <coding> <system value="http://loinc.org"/> <code value="58410-2"/> <display value="Complete blood count (hemogram) panel - Blood by Automated count"/> </coding> </code> <subject> <reference value="Patient/f001"/> <display value="P. van den Heuvel"/> </subject> <issued value="2013-05-15T19:32:52+01:00"/> <performer> <reference value="Organization/f001"/> <display value="Burgers University Medical Centre"/> </performer> <result> <reference value="Observation/f001"/> </result> <result> <reference value="Observation/f002"/> </result> <result> <reference value="Observation/f003"/> </result> <result> <reference value="Observation/f004"/> </result> <result> <reference value="Observation/f005"/> </result> <conclusion value="Core lab"/> </DiagnosticReport> </resource> </entry> <entry> <fullUrl value="https://example.com/base/ServiceRequest/req"/> <resource> <ServiceRequest> <id value="req"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : req</p> <p> <b> identifier</b> : id: L2381</p> <p> <b> status</b> : active</p> <p> <b> intent</b> : original-order</p> <p> <b> code</b> : <span> Complete blood count (hemogram) panel - Blood by Automated count</span> </p> <p> <b> subject</b> : <a> P. van den Heuvel. Generated Summary: id: f001; id: 738472983 (USUAL), id: ?ngen-9? (USUAL); active; Pieter van de Heuvel ; ph: 0648352638(MOBILE), p.heuvel@gmail.com(HOME); gender: male; birthDate: 1944-11-17; <span> Getrouwd</span> ; multipleBirth</a> </p> <p> <b> encounter</b> : <a> Generated Summary: id: f001; id: v1451 (OFFICIAL); status: completed; <span> ambulatory</span> ; <span> Patient-initiated encounter</span> ; <span> Non-urgent cardiological admission</span> ; 140 min; <span> Heart valve replacement</span> </a> </p> <p> <b> requester</b> : <a> E.van den Broek. Generated Summary: id: f001; id: 938273695 (OFFICIAL), id: 129IDH4OP733 (USUAL); Eric van den broek (OFFICIAL); ph: 0205568263(WORK), E.M.vandenbroek@bmc.nl(WORK), fax: 0205664440(WORK); gender: male; birthDate: 1975-12-07</a> </p> <p> <b> note</b> : patient almost fainted during procedure</p> </div> </text> <extension url="http://example.org/bodysitecode"> <valueCodeableConcept> <coding> <system value="http://snomed.info/sct"/> <code value="14975008"/> <display value="Forearm structure"/> </coding> </valueCodeableConcept> </extension> <identifier> <system value="http://www.bmc.nl/zorgportal/identifiers/labresults"/> <value value="L2381"/> </identifier> <status value="active"/> <intent value="original-order"/> <code> <coding> <system value="http://loinc.org"/> <code value="58410-2"/> <display value="Complete blood count (hemogram) panel - Blood by Automated count"/> </coding> </code> <subject> <reference value="Patient/f001"/> <display value="P. van den Heuvel"/> </subject> <encounter> <reference value="Encounter/f001"/> </encounter> <requester> <reference value="Practitioner/f001"/> <display value="E.van den Broek"/> </requester> <note> <text value="patient almost fainted during procedure"/> </note> </ServiceRequest> </resource> </entry> </Bundle>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.