This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: 3 | Trial Use | Compartments: N/A |
The Statistics operation performs a set of statistical calculations on a set of clinical measurements such as a blood pressure as stored on the server. This operation evaluates Observation resources having valueQuantity elements that have UCUM unit codes. Observations with a status of 'entered-in-error' will be excluded from the calculations.
The set of Observations is defined by 4 parameters:
subject
)code
and system
, or coding
)or
period`)statistic
)Possible statistical analyses (see StatisticsCode):
If successful, the operation returns an Observation resource for each code with the results of the statistical calculations as component value pairs where the component code = the statistical code. The Observation also contains the input parameters patient
,code
and duration
parameters. If unsuccessful, an OperationOutcome with an error message will be returned.
The client can request that all the observations on which the statistics are based be returned as well, using the include parameter. If an include parameter is specified, a limit may also be specified; the sources observations are subsetted at the server's discretion if count > limit. This functionality is included with the intent of supporting graphical presentation.
The official URL for this operation definition is
http://hl7.org/fhir/OperationDefinition/Observation-stats
Formal Definition (as a OperationDefinition).
URL: [base]/Observation/$stats
This is an idempotent operation
In Parameters: | |||||
Name | Cardinality | Type | Binding | Profile | Documentation |
subject | 1..1 | uri | The subject of the relevant Observations, which has the value of the Observation.subject.reference. E.g. 'Patient/123'. Reference can be to an absolute URL, but servers only perform stats on their own observations | ||
code | 0..* | string | The test code(s) upon which the statistics are being performed. Provide along with a system, or as a coding. For example, the LOINC code =
2339-0 (Glucose [Mass/volume] in Blood) will evaluate all relevant Observations with this code in | ||
system | 0..1 | uri | The system for the code(s). Or provide a coding instead | ||
coding | 0..* | Coding | The test code upon which the statistics are being performed, as a Coding | ||
duration | 0..1 | decimal | The time period of interest given as hours. For example, the duration = "1" represents the last hour - the time period from on hour ago to now | ||
period | 0..1 | Period | The time period over which the calculations to be performed, if a duration is not provided | ||
statistic | 1..* | code | average|max|min|count The statistical operations to be performed on the relevant operations. Multiple statistics operations can be specified. These codes are defined here | ||
include | 0..1 | boolean | Whether to return the observations on which the statistics are based | ||
limit | 0..1 | positiveInt | If an include parameter is specified, a limit may also be specified to limit the number of source Observations returned. If the include paramter is absent or equal to "false" the limit parameter SHALL be ignored by the server | ||
Out Parameters: | |||||
Name | Cardinality | Type | Binding | Profile | Documentation |
statistics | 1..* | Observation | A set of observations, one observation for each code, each containing one component for each statistic. The Observation.component.code contains the statistic, and is relative to the Observation.code and cannot be interpreted independently. The Observation will also contain a subject, effectivePeriod, and code reflecting the input parameters. The status is fixed to | ||
source | 0..* | Observation | Source observations on which the statistics are based |
If modifier extensions are present in the Observation, they must be accounted for by implementers. A modifier extension may affect the observation.value in a way that it should be excluded from the from the calculations.
This operation cannot be performed on observations that the user is not authorized to see. It is assumed that the server has identified and secured the context appropriately, and can either associate the authorization context with a single patient, or determine whether the context has the rights to the nominated patient, if there is one. If there is no nominated patient (e.g. the operation is invoked at the system level) and the context is not associated with a single patient record, then the server should return an error. Specifying the relationship between the context, a user and patient records is outside the scope of this specification.
Request: Get the average, min, max and count of a series of BP measurements for a patient
GET [base]/Observation/$stats?subject=Patient/123&code=85354-9&system=http://loinc.org&duration=1&statistic=average&statistic=min&statistic=max&statistic=count
Response:
<?xml version="1.0" encoding="UTF-8"?> <!-- The outcome for this particular operation is 2 Observation resources - one for the diastolic (8462-4) and one for the systolic components (8480-6), because the requested LOINC code is a panel code --> <Parameters xmlns="http://hl7.org/fhir"> <parameter> <name value="statistics"/> <resource> <Observation> <status value="final"/> <code> <coding> <system value="http://loinc.org"/> <code value="8480-6"/> <display value="Systolic blood pressure"/> </coding> </code> <subject> <reference value="Patient/123"/> </subject> <effectivePeriod> <start value="2016-05-25T19:26:16Z"/> <end value="2016-05-25T20:26:16Z"/> </effectivePeriod> <!--The Observation.component.code is relative to the Observation.code and cannot be interpreted independently.--> <component> <code> <!-- the average parameter code --> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="average"/> <display value="Average"/> </coding> </code> <valueQuantity> <value value="121.8"/> <unit value="mmHg"/> <system value="http://unitsofmeasure.org"/> <code value="mm[Hg]"/> </valueQuantity> </component> <component> <!-- the max parameter code --> <code> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="max"/> <display value="Maximum"/> </coding> </code> <valueQuantity> <value value="136"/> <unit value="mmHg"/> <system value="http://unitsofmeasure.org"/> <code value="mm[Hg]"/> </valueQuantity> </component> <component> <!-- the min parameter code --> <code> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="min"/> <display value="Minimum"/> </coding> </code> <valueQuantity> <value value="110"/> <unit value="mmHg"/> <system value="http://unitsofmeasure.org"/> <code value="mm[Hg]"/> </valueQuantity> </component> <component> <!-- the count parameter code --> <code> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="count"/> <display value="Count"/> </coding> </code> <valueQuantity> <value value="7"/> <system value="http://unitsofmeasure.org"/> <code value="{observations}"/> </valueQuantity> </component> </Observation> </resource> </parameter> <parameter> <name value="statistics"/> <resource> <Observation> <status value="final"/> <code> <coding> <system value="http://loinc.org"/> <code value="8462-4"/> <display value="Diastolic blood pressure"/> </coding> </code> <subject> <reference value="Patient/123"/> </subject> <effectivePeriod> <start value="2016-05-25T19:26:16Z"/> <end value="2016-05-25T20:26:16Z"/> </effectivePeriod> <!--The Observation.component.code is relative to the Observation.code and cannot be interpreted independently.--> <component> <code> <!-- the average parameter code --> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="average"/> <display value="Average"/> </coding> </code> <valueQuantity> <value value="79.7"/> <unit value="mmHg"/> <system value="http://unitsofmeasure.org"/> <code value="mm[Hg]"/> </valueQuantity> </component> <component> <!-- the max parameter code --> <code> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="max"/> <display value="Maximum"/> </coding> </code> <valueQuantity> <value value="110"/> <unit value="mmHg"/> <system value="http://unitsofmeasure.org"/> <code value="mm[Hg]"/> </valueQuantity> </component> <component> <!-- the min parameter code --> <code> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="min"/> <display value="Minimum"/> </coding> </code> <valueQuantity> <value value="56"/> <unit value="mmHg"/> <system value="http://unitsofmeasure.org"/> <code value="mm[Hg]"/> </valueQuantity> </component> <component> <!-- the count parameter code --> <code> <coding> <system value="http://hl7.org/fhir/observation-paramcode"/> <code value="count"/> <display value="Count"/> </coding> </code> <valueQuantity> <value value="7"/> <system value="http://unitsofmeasure.org"/> <code value="{observations}"/> </valueQuantity> </component> </Observation> </resource> </parameter> </Parameters>
For more information about operations, including how they are invoked, see Operations.