R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3

Observation-example-genetics-5.xml

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Genetics example 5 (id = "example-genetics-5")

<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="example-genetics-5"/> 


  <!--    replaced the .related type sequel to with an extension    -->

  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example-genetics-5</p> <p> <b> status</b> : final</p> <p> <b> code</b> : PCR validation <span> (Details )</span> </p> <p> <b> subject</b> : <a> Molecular Lab Patient ID: HOSP-23456</a> </p> <p> <b> issued</b> : 03/04/2013 3:30:10 PM</p> <p> <b> performer</b> : <a> Sequence Analysis Laboratory</a> </p> <p> <b> value</b> : Negative <span> (Details : {SNOMED CT code '260385009' = 'Negative', given as 'Negative'})</span> </p> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/observation-sequelTo">
    <valueReference> 
      <reference value="Observation/example-genetics-1"/> 
      <display value="ObservationForGenetics profile example 1"/> 
    </valueReference> 
  </extension> 
  <!--   
  <related>
    <type value="sequel-to"/>
    <target>
      <reference value="Observation/example-genetics-1"/>
      <display value="ObservationForGenetics profile example 1"/>
    </target>
  </related>
   -->
  <status value="final"/> 
  <code> 
    <text value="PCR validation"/> 
  </code> 
  <subject> 
    <reference value="Patient/example"/> 
    <display value="Molecular Lab Patient ID: HOSP-23456"/> 
  </subject> 
  <issued value="2013-04-03T15:30:10+01:00"/> 
  <performer> 
    <reference value="Practitioner/example"/> 
    <display value="Sequence Analysis Laboratory"/> 
  </performer> 
  <valueCodeableConcept> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="260385009"/> 
      <display value="Negative"/> 
    </coding> 
  </valueCodeableConcept> 
</Observation> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.