R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Orders and Observations Work GroupMaturity Level: 5 Normative Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Detailed Descriptions for the elements in the Observation resource.

Observation
Element IdObservation
Definition

Measurements and simple assertions made about a patient, device or other subject.

Control1..1
TypeDomainResource
Requirements

Observations are a key aspect of healthcare. This resource is used to capture those that do not require more sophisticated mechanisms.

Alternate NamesVital Signs; Measurement; Results; Tests
Comments

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Invariants
Defined on this element
obs-6Rule dataAbsentReason SHALL only be present if Observation.value[x] is not presentdataAbsentReason.empty() or value.empty()
obs-7Rule If Observation.code is the same as a Observation.component.code then the value element associated with the code SHALL NOT be presentvalue.empty() or component.code.where( (coding.code = %resource.code.coding.code) and (coding.system = %resource.code.coding.system)).empty()
Observation.identifier
Element IdObservation.identifier
Definition

A unique identifier assigned to this observation.

NoteThis is a business identifer, not a resource identifier (see discussion)
Control0..*
TypeIdentifier
Requirements

Allows observations to be distinguished and referenced.

Summarytrue
Observation.basedOn
Element IdObservation.basedOn
Definition

A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

Control0..*
TypeReference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)
Requirements

Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

Alternate NamesFulfills
Summarytrue
Observation.partOf
Element IdObservation.partOf
Definition

A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

Control0..*
TypeReference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)
Alternate NamesContainer
Summarytrue
Comments

To link an Observation to an Encounter use context. See the Notes below for guidance on referencing another Observation.

Observation.status
Element IdObservation.status
Definition

The status of the result value.

Control1..1
Terminology BindingObservationStatus (Required)
Typecode
Is Modifiertrue (Reason: This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid)
Requirements

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Summarytrue
Comments

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Observation.category
Element IdObservation.category
Definition

A code that classifies the general type of observation being made.

Control0..*
Terminology BindingObservation Category Codes (Preferred)
TypeCodeableConcept
Requirements

Used for filtering what observations are retrieved and displayed.

Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Observation.code
Element IdObservation.code
Definition

Describes what was observed. Sometimes this is called the observation "name".

Control1..1
Terminology BindingLOINC Codes (Example)
TypeCodeableConcept
Requirements

Knowing what kind of observation is being made is essential to understanding the observation.

Alternate NamesName
Summarytrue
Comments

All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Observation.subject
Element IdObservation.subject
Definition

The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

Control0..1
TypeReference(Patient | Group | Device | Location)
Requirements

Observations have no value if you don't know who or what they're about.

Summarytrue
Comments

One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

Observation.focus
Element IdObservation.focus
Definition

The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

Control0..*
TypeReference(Any)
Summarytrue
Comments

Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension focusCode.

Observation.encounter
Element IdObservation.encounter
Definition

The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

Control0..1
TypeReference(Encounter)
Requirements

For some observations it may be important to know the link between an observation and a particular encounter.

Alternate NamesContext
Summarytrue
Comments

This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

Observation.effective[x]
Element IdObservation.effective[x]
Definition

The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

Control0..1
TypedateTime|Period|Timing|instant
[x] NoteSee Choice of Data Types for further information about how to use [x]
Requirements

Knowing when an observation was deemed true is important to its relevance as well as determining trends.

Alternate NamesOccurrence
Summarytrue
Comments

At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

Observation.issued
Element IdObservation.issued
Definition

The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

Control0..1
Typeinstant
Summarytrue
Comments

For Observations that don’t require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.

Observation.performer
Element IdObservation.performer
Definition

Who was responsible for asserting the observed value as "true".

Control0..*
TypeReference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)
Requirements

May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

Summarytrue
Observation.value[x]
Element IdObservation.value[x]
Definition

The information determined as a result of making the observation, if the information has a simple value.

Control0..1
TypeQuantity|CodeableConcept|string|boolean|integer|Range|Ratio|SampledData|time|dateTime|Period
[x] NoteSee Choice of Data Types for further information about how to use [x]
Requirements

An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

Summarytrue
Comments

An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

Invariants
Affect this element
obs-7Rule If Observation.code is the same as a Observation.component.code then the value element associated with the code SHALL NOT be presentvalue.empty() or component.code.where( (coding.code = %resource.code.coding.code) and (coding.system = %resource.code.coding.system)).empty()
Observation.dataAbsentReason
Element IdObservation.dataAbsentReason
Definition

Provides a reason why the expected value in the element Observation.value[x] is missing.

Control0..1
Terminology BindingDataAbsentReason (Extensible)
TypeCodeableConcept
Requirements

For many results it is necessary to handle exceptional values in measurements.

Comments

Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

Invariants
Affect this element
obs-6Rule dataAbsentReason SHALL only be present if Observation.value[x] is not presentdataAbsentReason.empty() or value.empty()
Observation.interpretation
Element IdObservation.interpretation
Definition

A categorical assessment of an observation value. For example, high, low, normal.

Control0..*
Terminology BindingObservation Interpretation Codes (Extensible)
TypeCodeableConcept
Requirements

For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

Alternate NamesAbnormal Flag
Comments

Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

Observation.comment
Element IdObservation.comment
Definition

Comments about the test result value may include statements about significant, unexpected or unreliable results values, or information about the its source when this is relevant to its interpretation.

Control0..1
Typestring
Requirements

Need to be able to provide free text additional information.

Observation.bodySite
Element IdObservation.bodySite
Definition

Indicates the site on the subject's body where the observation was made (i.e. the target site).

Control0..1
Terminology BindingSNOMED CT Body Structures (Example)
TypeCodeableConcept
Comments

Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite.

Observation.method
Element IdObservation.method
Definition

Indicates the mechanism used to perform the observation.

Control0..1
Terminology BindingObservation Methods (Example)
TypeCodeableConcept
Requirements

In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

Comments

Only used if not implicit in code for Observation.code.

Observation.specimen
Element IdObservation.specimen
Definition

The specimen that was used when this observation was made.

Control0..1
TypeReference(Specimen)
Comments

Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

Observation.device
Element IdObservation.device
Definition

The device used to generate the observation data.

Control0..1
TypeReference(Device | DeviceMetric)
Comments

An extension should be used if further typing of the device is needed. Devices used to support obtaining an observation can be represented using an extension or the Provenance resource. (e.g., a device gateway such as a smart phone).

Observation.referenceRange
Element IdObservation.referenceRange
Definition

Guidance on how to interpret the value by comparison to a normal or recommended range.

Control0..*
Requirements

Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

Comments

Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

Invariants
Defined on this element
obs-3Rule Must have at least a low or a high or textlow.exists() or high.exists() or text.exists()
Observation.referenceRange.low
Element IdObservation.referenceRange.low
Definition

The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3).

Control0..1
TypeSimpleQuantity
Invariants
Affect this element
obs-3Rule Must have at least a low or a high or textlow.exists() or high.exists() or text.exists()
Observation.referenceRange.high
Element IdObservation.referenceRange.high
Definition

The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3).

Control0..1
TypeSimpleQuantity
Invariants
Affect this element
obs-3Rule Must have at least a low or a high or textlow.exists() or high.exists() or text.exists()
Observation.referenceRange.type
Element IdObservation.referenceRange.type
Definition

Codes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range.

Control0..1
Terminology BindingObservation Reference Range Meaning Codes (Preferred)
TypeCodeableConcept
Requirements

Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation.

Comments

This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed.

Observation.referenceRange.appliesTo
Element IdObservation.referenceRange.appliesTo
Definition

Codes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race.

Control0..*
Terminology BindingObservation Reference Range Applies To Codes (Example)
TypeCodeableConcept
Requirements

Need to be able to identify the target population for proper interpretation.

Comments

This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed.

Observation.referenceRange.age
Element IdObservation.referenceRange.age
Definition

The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so.

Control0..1
TypeRange
Requirements

Some analytes vary greatly over age.

Observation.referenceRange.text
Element IdObservation.referenceRange.text
Definition

Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals".

Control0..1
Typestring
Observation.hasMember
Element IdObservation.hasMember
Definition

This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

Control0..*
TypeReference(Observation | QuestionnaireResponse | Sequence)
Summarytrue
Comments

When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

Observation.derivedFrom
Element IdObservation.derivedFrom
Definition

The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

Control0..*
TypeReference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | Sequence)
Summarytrue
Comments

All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

Observation.component
Element IdObservation.component
Definition

Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

Control0..*
Requirements

Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

Summarytrue
Comments

For a discussion on the ways Observations can be assembled in groups together see Notes below.

Observation.component.code
Element IdObservation.component.code
Definition

Describes what was observed. Sometimes this is called the observation "code".

Control1..1
Terminology BindingLOINC Codes (Example)
TypeCodeableConcept
Requirements

Knowing what kind of observation is being made is essential to understanding the observation.

Summarytrue
Comments

All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Observation.component.value[x]
Element IdObservation.component.value[x]
Definition

The information determined as a result of making the observation, if the information has a simple value.

Control0..1
TypeQuantity|CodeableConcept|string|boolean|integer|Range|Ratio|SampledData|time|dateTime|Period
[x] NoteSee Choice of Data Types for further information about how to use [x]
Requirements

An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

Summarytrue
Comments

Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

Observation.component.dataAbsentReason
Element IdObservation.component.dataAbsentReason
Definition

Provides a reason why the expected value in the element Observation.component.value[x] is missing.

Control0..1
Terminology BindingDataAbsentReason (Extensible)
TypeCodeableConcept
Requirements

For many results it is necessary to handle exceptional values in measurements.

Comments

"Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

Invariants
Affect this element
obs-6Rule dataAbsentReason SHALL only be present if Observation.value[x] is not presentdataAbsentReason.empty() or value.empty()
Observation.component.interpretation
Element IdObservation.component.interpretation
Definition

A categorical assessment of an observation value. For example, high, low, normal.

Control0..*
Terminology BindingObservation Interpretation Codes (Extensible)
TypeCodeableConcept
Requirements

For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

Alternate NamesAbnormal Flag
Comments

Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

Observation.component.referenceRange
Element IdObservation.component.referenceRange
Definition

Guidance on how to interpret the value by comparison to a normal or recommended range.

Control0..*
TypeSee Observation.referenceRange
Requirements

Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

Comments

Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.