R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3 R2

Media-example-dicom.json

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Patient, Practitioner

Raw JSON (canonical form)

Example Ultrasound Image

{
  "resourceType": "Media",
  "id": "1.2.840.11361907579238403408700.3.1.04.19970327150033",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n      Ultrasound Image on patient &quot;James Chalmers&quot;:<br/>\n      <img src=\"http://imaging.acme.com/wado/server?requestType=WADO&amp;contentType=application%2Fdicom&amp;studyUid=1.2.840.113619.2.21.848.34082.0.538976288.3&amp;seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.3.0&amp;objectUid=1.2.840.11361907579238403408700.3.1.04.19970327150033\" alt=\"WADO reference to image\"/>\n\n    </div>"
  },
  "extension": [
    {
      "url": "http://nema.org/fhir/extensions#0002-0010",
      "valueUri": "urn:oid:1.2.840.10008.1.2.1"
    }
  ],
  "identifier": [
    {
      "use": "official",
      "type": {
        "text": "InstanceUID"
      },
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:1.2.840.11361907579238403408700.3.1.04.19970327150033"
    },
    {
      "type": {
        "text": "accessionNo"
      },
      "system": "http://acme-imaging.com/accession/2012",
      "value": "1234567"
    },
    {
      "type": {
        "text": "studyId"
      },
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:1.2.840.113619.2.21.848.34082.0.538976288.3"
    },
    {
      "type": {
        "text": "seriesId"
      },
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:1.2.840.113619.2.21.3408.700.0.757923840.3.0"
    }
  ],
  "status": "completed",
  "modality": {
    "coding": [
      {
        "system": "http://dicom.nema.org/resources/ontology/DCM",
        "code": "US"
      }
    ]
  },
  "view": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "399067008",
        "display": "Lateral projection"
      }
    ]
  },
  "subject": {
    "reference": "Patient/example"
  },
  "device": {
    "display": "G.E. Medical Systems"
  },
  "height": 480,
  "width": 640,
  "content": {
    "contentType": "application/dicom",
    "url": "http://imaging.acme.com/wado/server?requestType=WADO&contentType=application%2Fdicom&studyUid=1.2.840.113619.2.21.848.34082.0.538976288.3&seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.3.0&objectUid=1.2.840.11361907579238403408700.3.1.04.19970327150033"
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.