This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3 R2
Example Ultrasound Image
{ "resourceType": "Media", "id": "1.2.840.11361907579238403408700.3.0.14.19970327150033", "text": { "fhir_comments": [ " \n This example demonstrates how to represent an image \n originally sourced by a DICOM acquisition device\n as a Media resource. Whether this is appropriate depends\n on the complexity of the image - the media resource only\n contains crude metadata, and plain png/jpg (typically)\n pixels. This is suitable for the bulk of simple images\n shared as summaries with consumers, but not at all suitable \n for other kinds of images, or for internal radiology \n reporting usage \n " ], "status": "generated", "div": "<div>\n Ultrasound Image on patient "James Chalmers":<br/>\n <img alt=\"WADO reference to image\" src=\"http://imaging.acme.com/wado/server?requestType=WADO&contentType=application%2Fdicom&studyUid=1.2.840.113619.2.21.848.34082.0.538976288.3&seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.3.0&objectUid=1.2.840.11361907579238403408700.3.0.14.19970327150033\"/>\n \n </div>" }, "extension": [ { "fhir_comments": [ " \n this is added to demonstrate the use of DICOM extensions.\n 0002,0010 is the DICOM transfer syntax of the referenced image\n " ], "url": "http://nema.org/fhir/extensions#0002-0010", "valueUri": "urn:oid:1.2.840.10008.1.2.1" } ], "type": "photo", "subtype": { "coding": [ { "system": "http://nema.org/dicom/dicm", "code": "US" } ] }, "identifier": [ { "use": "official", "type": { "text": "InstanceUID" }, "system": "urn:ietf:rfc:3986", "value": "urn:oid:1.2.840.11361907579238403408700.3.0.14.19970327150033" }, { "type": { "text": "accessionNo" }, "system": "http://acme-imaging.com/accession/2012", "_system": { "fhir_comments": [ " the imaging department accession number. (they recycle numbers each year) " ] }, "value": "1234567" }, { "type": { "text": "studyId" }, "system": "urn:ietf:rfc:3986", "value": "urn:oid:1.2.840.113619.2.21.848.34082.0.538976288.3" }, { "type": { "text": "seriesId" }, "system": "urn:ietf:rfc:3986", "value": "urn:oid:1.2.840.113619.2.21.3408.700.0.757923840.3.0" } ], "subject": { "reference": "Patient/example" }, "view": { "coding": [ { "system": "http://snomed.info/sct", "code": "399067008", "display": "Lateral projection" } ] }, "deviceName": "G.E. Medical Systems", "height": 480, "width": 640, "content": { "fhir_comments": [ " and a reference to the image data " ], "contentType": "application/dicom", "url": "http://imaging.acme.com/wado/server?requestType=WADO&contentType=application%2Fdicom&studyUid=1.2.840.113619.2.21.848.34082.0.538976288.3&seriesUid=1.2.840.113619.2.21.3408.700.0.757923840.3.0&objectUid=1.2.840.11361907579238403408700.3.0.14.19970327150033", "_url": { "fhir_comments": [ " The actual image could be anywhere. This is a WADO example " ] } } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.