STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

4.3.1.62 Value Set http://hl7.org/fhir/ValueSet/observation-vitalsignresult

This is a value set defined by the FHIR project.

Summary

Defining URL:http://hl7.org/fhir/ValueSet/observation-vitalsignresult
Name:Vital Signs
Definition:This value set indicates the allowed vital sign result types. The concept Vitals Signs Panel (8716-3) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP). The Blood pressure systolic and diastolic (55284-4) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).
Committee:Orders and Observations Work Group
OID:2.16.840.1.113883.3.88.12.80.62 (for OID based terminology systems)
Copyright:This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use
Source ResourceXML / JSON

This value set is used in the following places:


This value set includes codes from the following code systems:

  • Include these codes as defined in http://loinc.org
    CodeDisplay
    8716-3Vital signs
    9279-1Respiratory rate
    8867-4Heart rate
    59408-5Oxygen saturation in Arterial blood by Pulse oximetry
    8310-5Body temperature
    8302-2Body height
    8306-3Body height --lying
    8287-5Head Occipital-frontal circumference by Tape measure
    29463-7Body weight
    39156-5Body mass index (BMI) [Ratio]
    55284-4Blood pressure systolic and diastolic
    8480-6Systolic blood pressure
    8462-4Diastolic blood pressure
    8478-0Mean blood pressure

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

LevelA few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
SourceThe source of the definition of the code (when the value set draws in codes defined elsewhere)
CodeThe code (used as the code in the resource instance)
DisplayThe display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
DefinitionAn explanation of the meaning of the concept
CommentsAdditional notes about how to use the code