This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
This is a value set defined by the FHIR project.
Summary
Defining URL: | http://hl7.org/fhir/ValueSet/observation-interpretation |
Name: | Observation Interpretation Codes |
Definition: | This value set defines the set of codes that can be used to indicate the meaning/use of a reference range. |
Committee: | Orders and Observations Work Group |
OID: | 2.16.840.1.113883.4.642.2.218 (for OID based terminology systems) |
Source Resource | XML / JSON |
This value set is used in the following places:
This value set includes codes from the following code systems:
This expansion generated 06 Dec 2016
This value set contains 39 concepts
Expansion based on http://hl7.org/fhir/v2/0078 version 2.8.2
All codes from system http://hl7.org/fhir/v2/0078
Code | Display | Definition |
< | Off scale low | |
> | Off scale high | |
A | Abnormal | |
AA | Critically abnormal | |
AC | Anti-complementary substances present | |
B | Better | |
D | Significant change down | |
DET | Detected | |
H | High | |
HH | Critically high | |
HM | Hold for Medical Review | |
HU | Very high | |
I | Intermediate | |
IE | Insufficient evidence | |
IND | Indeterminate | |
L | Low | |
LL | Critically low | |
LU | Very low | |
MS | Moderately susceptible. Indicates for microbiology susceptibilities only. | |
N | Normal | |
ND | Not Detected | |
NEG | Negative | |
NR | Non-reactive | |
NS | Non-susceptible | |
null | No range defined, or normal ranges don't apply | |
OBX | Interpretation qualifiers in separate OBX segments | |
POS | Positive | |
QCF | Quality Control Failure | |
R | Resistant | |
RR | Reactive | |
S | Susceptible | |
SDD | Susceptible-dose dependent | |
SYN-R | Synergy - resistant | |
SYN-S | Synergy - susceptible | |
TOX | Cytotoxic substance present | |
U | Significant change up | |
VS | Very susceptible. Indicates for microbiology susceptibilities only. | |
W | Worse | |
WR | Weakly reactive |
Additional Language Displays
Code | Deutsch (German, de) | Nederlands (Dutch, nl) |
< | Unter Meßbereich (Extremwertverletzung) | Onder absolute ondergrens instrumentschaal |
> | Über Meßbereich (Extremwertverletzung) | Boven absolute bovengrens instrumentschaal |
A | anormal (nicht numerisch) | Abnormaal |
AA | Pathologisch (nicht numerisch) | Kritiek abnormaal |
AC | Anti-complementaire stoffen aanwezig | |
B | Verbesserung | Beter |
D | Deutlicher Trend nach unten | Significante wijzging omlaag |
DET | Gedetecteerd | |
H | Oberhalb oberer Grenze Referenzbereich | Hoog |
HH | Oberhalb oberer pathologischer Grenze | Kritiek hoog |
HM | Vastgehouden voor medische review | |
HU | Zeer hoog | |
I | Intermediär | Gemiddeld |
IE | Onvoldoende bewijs | |
IND | Onbepaald | |
L | Unterhalb unterer Grenze Referenzbereich | Laag |
LL | Unterhalb unterer pathologischer Grenze | Kritiek laag |
LU | Zeer laag | |
MS | mäßig empfindlich | Gemiddeld gevoelig. Alleen voor microbiologische gevoeligheid. |
N | Normal (nicht numerisch) | Normaal |
ND | Niet-gedetecteerd | |
NEG | Negatief | |
NR | Niet-reactief | |
NS | Niet-gevoelig | |
null | Kein Referenzbereich / Referenzbereich nicht anwendbar | Geen referentiewaarden gedefinieerd of normale waarden niet van toepassing |
OBX | Interpretatie qualifiers in afzonderlijke OBX-segmenten | |
POS | Positief | |
QCF | Kwaliteitscontrole fout | |
R | Resistent | Resistent |
RR | Reactief | |
S | Empfindlich | Gevoelig |
SDD | Gevoelig dosis-afhankelijk | |
SYN-R | Synergie - resistent | |
SYN-S | Synergie - gevoelig | |
TOX | Cytotoxische stoffen aanwezig | |
U | Deutlicher Trend nach oben | Significante wijzging omhoog |
VS | Sehr empfindlich | Zeer gevoelig. Alleen voor microbiologische gevoeligheid. |
W | Verschlechterung | Slechter |
WR | Zwak reactief |
See the full registry of value sets defined as part of FHIR.
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |