STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0376.vs.xml

Raw XML (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0376 ( Special Handling Code)

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="v2-0376"/>
  <meta>
    <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/>
  </meta>
  <text>
    <status value="additional"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p>Special Handling Code</p>

      <table class="grid">
        <tr>
          <td>
            <b>Code</b>
          </td>
          <td>
            <b>Description</b>
          </td>
          <td>
            <b>Comment</b>
          </td>
          <td>
            <b>Version</b>
          </td>
        </tr>
        <tr>
          <td>AMB
            <a name="AMB"> </a>
          </td>
          <td>Ambient temperature</td>
          <td>Keep at ambient (room) temperature, approximately 22 ( 2 degrees C. Accidental refrigeration
               or freezing is of little consequence</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>C37
            <a name="C37"> </a>
          </td>
          <td>Body temperature</td>
          <td>Critical to keep at body temperature: 36 - 38( C.</td>
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>CAMB
            <a name="CAMB"> </a>
          </td>
          <td>Critical ambient temperature</td>
          <td>Critical ambient - must not be refrigerated or frozen.</td>
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>CATM
            <a name="CATM"> </a>
          </td>
          <td>Protect from air</td>
          <td>Critical. Do not expose to atmosphere. Do not uncap.</td>
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>CFRZ
            <a name="CFRZ"> </a>
          </td>
          <td>Critical frozen temperature</td>
          <td>Critical frozen - must not be allowed to thaw until immediately prior to testing</td>
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>CREF
            <a name="CREF"> </a>
          </td>
          <td>Critical refrigerated temperature</td>
          <td>Critical refrigerated -  must not be allowed to freeze or warm until immediately prior
               to testing</td>
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>DFRZ
            <a name="DFRZ"> </a>
          </td>
          <td>Deep frozen</td>
          <td>Deep frozen: -16 to -20( C.</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>DRY
            <a name="DRY"> </a>
          </td>
          <td>Dry</td>
          <td>Keep in a dry environment.</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>FRZ
            <a name="FRZ"> </a>
          </td>
          <td>Frozen temperature</td>
          <td>Keep at frozen temperature: -4( C. Accidental thawing is of little consequence</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>MTLF
            <a name="MTLF"> </a>
          </td>
          <td>Metal Free</td>
          <td>Container is free of heavy metals including lead.</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>NTR
            <a name="NTR"> </a>
          </td>
          <td>Liquid nitrogen</td>
          <td>Keep in liquid nitrogen.</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>PRTL
            <a name="PRTL"> </a>
          </td>
          <td>Protect from light</td>
          <td>Protect from light (e.g. wrap in aluminum foil).</td>
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>PSA
            <a name="PSA"> </a>
          </td>
          <td>Do not shake</td>
          <td>Do not shake.</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>PSO
            <a name="PSO"> </a>
          </td>
          <td>No shock</td>
          <td>Protect from shock.</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>REF
            <a name="REF"> </a>
          </td>
          <td>Refrigerated temperature</td>
          <td>Keep at refrigerated temperature: 4-8( C. Accidental warming or freezing is of little
               consequence</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>UFRZ
            <a name="UFRZ"> </a>
          </td>
          <td>Ultra frozen</td>
          <td>Ultra cold frozen: ~ -75 to -85( C. (ultra cold freezer is typically at temperature of
               dry ice).</td>
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>UPR
            <a name="UPR"> </a>
          </td>
          <td>Upright</td>
          <td>Keep upright. Do not turn upside down.</td>
          <td>added v2.5</td>
        </tr>
      </table>

    </div>
  </text>
  <url value="http://hl7.org/fhir/ValueSet/v2-0376"/>
  <version value="2.8.2"/>
  <name value="v2 Special Handling Code"/>
  <status value="active"/>
  <experimental value="true"/>
  <publisher value="HL7, Inc"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://hl7.org"/>
    </telecom>
  </contact>
  <description value="FHIR Value set/code system definition for HL7 v2 table 0376 ( Special Handling Code)"/>
  <immutable value="true"/>
  <compose>
    <include>
      <system value="http://hl7.org/fhir/v2/0376"/>
    </include>
  </compose>
</ValueSet>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.