This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3
Vocabulary Work Group | Maturity Level: N/A | Standards Status: Informative |
Raw XML (canonical form + also see XML Format Specification)
FHIR Value set/code system definition for HL7 v2 table 0376 ( Special handling considerations)
<?xml version="1.0" encoding="UTF-8"?> <ValueSet xmlns="http://hl7.org/fhir"> <id value="v2-0376"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/> </meta> <language value="en"/> <text> <status value="additional"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p> Special Handling Code</p> <table class="grid"> <tr> <td> <b> Code</b> </td> <td> <b> Description</b> </td> <td> <b> Comment</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td> AMB <a name="AMB"> </a> </td> <td> Ambient temperature</td> <td> Keep at ambient (room) temperature, approximately 22 ( 2 degrees C. Accidental refrigeration or freezing is of little consequence</td> <td> added v2.5</td> </tr> <tr> <td> C37 <a name="C37"> </a> </td> <td> Body temperature</td> <td> Critical to keep at body temperature: 36 - 38( C.</td> <td> added v2.4</td> </tr> <tr> <td> CAMB <a name="CAMB"> </a> </td> <td> Critical ambient temperature</td> <td> Critical ambient - must not be refrigerated or frozen.</td> <td> added v2.4</td> </tr> <tr> <td> CATM <a name="CATM"> </a> </td> <td> Protect from air</td> <td> Critical. Do not expose to atmosphere. Do not uncap.</td> <td> added v2.4</td> </tr> <tr> <td> CFRZ <a name="CFRZ"> </a> </td> <td> Critical frozen temperature</td> <td> Critical frozen - must not be allowed to thaw until immediately prior to testing</td> <td> added v2.4</td> </tr> <tr> <td> CREF <a name="CREF"> </a> </td> <td> Critical refrigerated temperature</td> <td> Critical refrigerated - must not be allowed to freeze or warm until immediately prior to testing</td> <td> added v2.4</td> </tr> <tr> <td> DFRZ <a name="DFRZ"> </a> </td> <td> Deep frozen</td> <td> Deep frozen: -16 to -20( C.</td> <td> added v2.5</td> </tr> <tr> <td> DRY <a name="DRY"> </a> </td> <td> Dry</td> <td> Keep in a dry environment.</td> <td> added v2.5</td> </tr> <tr> <td> FRZ <a name="FRZ"> </a> </td> <td> Frozen temperature</td> <td> Keep at frozen temperature: -4( C. Accidental thawing is of little consequence</td> <td> added v2.5</td> </tr> <tr> <td> MTLF <a name="MTLF"> </a> </td> <td> Metal Free</td> <td> Container is free of heavy metals including lead.</td> <td> added v2.5</td> </tr> <tr> <td> NTR <a name="NTR"> </a> </td> <td> Liquid nitrogen</td> <td> Keep in liquid nitrogen.</td> <td> added v2.5</td> </tr> <tr> <td> PRTL <a name="PRTL"> </a> </td> <td> Protect from light</td> <td> Protect from light (e.g., wrap in aluminum foil).</td> <td> added v2.4</td> </tr> <tr> <td> PSA <a name="PSA"> </a> </td> <td> Do not shake</td> <td> Do not shake.</td> <td> added v2.5</td> </tr> <tr> <td> PSO <a name="PSO"> </a> </td> <td> No shock</td> <td> Protect from shock.</td> <td> added v2.5</td> </tr> <tr> <td> REF <a name="REF"> </a> </td> <td> Refrigerated temperature</td> <td> Keep at refrigerated temperature: 4-8( C. Accidental warming or freezing is of little consequence</td> <td> added v2.5</td> </tr> <tr> <td> UFRZ <a name="UFRZ"> </a> </td> <td> Ultra frozen</td> <td> Ultra cold frozen: ~ -75 to -85( C. (ultra cold freezer is typically at temperature of dry ice).</td> <td> added v2.5</td> </tr> <tr> <td> UPR <a name="UPR"> </a> </td> <td> Upright</td> <td> Keep upright. Do not turn upside down.</td> <td> added v2.5</td> </tr> </table> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"> <valueCode value="external"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="0"/> </extension> <url value="http://terminology.hl7.org/ValueSet/v2-0376"/> <version value="2.9"/> <name value="v2.0376"/> <title value="v2 Special handling considerations"/> <status value="active"/> <experimental value="false"/> <publisher value="HL7, Inc"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org"/> </telecom> </contact> <description value="FHIR Value set/code system definition for HL7 v2 table 0376 ( Special handling considerations)"/> <immutable value="true"/> <compose> <include> <system value="http://terminology.hl7.org/CodeSystem/v2-0376"/> </include> </compose> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.