This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Implantable device/UDI example ICCBBA Format
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Device/example-udi2> a fhir:Device; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "example-udi2"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-udi2</p><p><b>udiCarrier</b>: Universal Device Identifier = =+05037=/A9999XYZ100T0474=,000025=A99971312345600=>014032=}013032</p><p><b>status</b>: not-available</p><p><b>type</b>: DI = A9999XYZ100T0474 <span>(Details : {http://hl7.org/fhir/NamingSystem/iccbba-other-di code 'A9999XYZ100T0474' = 'A9999XYZ100T0474)</span></p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>manufactureDate</b>: 01/02/2013</p><p><b>expirationDate</b>: 01/02/2014</p><p><b>model</b>: Bone,Putty Demineralized</p><p><b>patient</b>: <a>Patient/example</a></p></div>" ]; fhir:extension [ fhir:index 0; fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/device-din" ]; fhir:Extension.valueIdentifier [ fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-din" ]; fhir:Identifier.value [ fhir:value "A99971312345600" ] ] ]; fhir:Device.udiCarrier [ fhir:Identifier.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ]; fhir:Coding.code [ fhir:value "UDI" ] ] ]; fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ]; fhir:Identifier.value [ fhir:value "=+05037=/A9999XYZ100T0474=,000025=A99971312345600=>014032=}013032" ] ]; fhir:Device.status [ fhir:value "not-available"]; fhir:Device.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-other-di" ]; fhir:Coding.code [ fhir:value "A9999XYZ100T0474" ] ]; fhir:CodeableConcept.text [ fhir:value "DI = A9999XYZ100T0474" ] ]; fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"]; fhir:Device.manufactureDate [ fhir:value "2013-02-01"^^xsd:date]; fhir:Device.expirationDate [ fhir:value "2014-02-01"^^xsd:date]; fhir:Device.model [ fhir:value "Bone,Putty Demineralized"]; fhir:Device.patient [ fhir:link <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ] . <http://hl7.org/fhir/Patient/example> a fhir:Patient . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.