This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Serum Sample
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Specimen/sst> a fhir:Specimen; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "sst"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: sst</p><p><b>accessionIdentifier</b>: 20150816-00124</p><p><b>type</b>: Serum sample <span>(Details : {SNOMED CT code '119364003' = 'Serum specimen (specimen)', given as 'Serum sample'})</span></p><p><b>subject</b>: <a>Patient/pat2</a></p><p><b>request</b>: <a>DiagnosticRequest/ft4</a></p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td><a>Practitioner/f202</a></td><td>16/08/2015 4:40:17 PM</td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Type</b></td></tr><tr><td>*</td><td>Serum Separator Tube <span>(Details : {http://acme.com/labs code 'SST' = '??', given as 'Serum Separator Tube'})</span></td></tr></table></div>" ]; fhir:Specimen.accessionIdentifier [ fhir:Identifier.system [ fhir:value "http://acme.com/labs/accession-ids" ]; fhir:Identifier.value [ fhir:value "20150816-00124" ] ]; fhir:Specimen.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:119364003; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "119364003" ]; fhir:Coding.display [ fhir:value "Serum sample" ] ] ]; fhir:Specimen.subject [ fhir:link <http://hl7.org/fhir/Patient/pat2>; fhir:Reference.reference [ fhir:value "Patient/pat2" ] ]; fhir:Specimen.request [ fhir:index 0; fhir:link <http://hl7.org/fhir/DiagnosticRequest/ft4>; fhir:Reference.reference [ fhir:value "DiagnosticRequest/ft4" ] ]; fhir:Specimen.collection [ fhir:Specimen.collection.collector [ fhir:link <http://hl7.org/fhir/Practitioner/f202>; fhir:Reference.reference [ fhir:value "Practitioner/f202" ] ]; fhir:Specimen.collection.collectedDateTime [ fhir:value "2015-08-16T06:40:17Z"^^xsd:dateTime ] ]; fhir:Specimen.container [ fhir:index 0; fhir:Specimen.container.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://acme.com/labs" ]; fhir:Coding.code [ fhir:value "SST" ]; fhir:Coding.display [ fhir:value "Serum Separator Tube" ] ] ] ] . <http://hl7.org/fhir/Patient/pat2> a fhir:Patient . <http://hl7.org/fhir/DiagnosticRequest/ft4> a fhir:DiagnosticRequest . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.