STU 3 Ballot

This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Observation-example-bloodpressure-cancel.ttl

Raw Turtle, JSON-LD

Blood Pressure Measurement cancelled

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/owl#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Observation/blood-pressure-cancel> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "blood-pressure-cancel"];
  fhir:Resource.meta [
     fhir:Meta.lastUpdated [ fhir:value "2014-01-30T22:35:23+11:00"^^xsd:dateTime ]
  ];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: blood-pressure-cancel</p><p><b>meta</b>: </p><p><b>identifier</b>: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</p><p><b>status</b>: cancelled</p><p><b>code</b>: Blood pressure systolic &amp; diastolic <span>(Details : {LOINC code '55284-4' = 'Blood pressure systolic and diastolic', given as 'Blood pressure systolic &amp; diastolic'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 17/09/2012</p><p><b>performer</b>: <a>Practitioner/example</a></p><p><b>interpretation</b>: Below low normal <span>(Details : {http://hl7.org/fhir/v2/0078 code 'L' = 'Low', given as 'low'})</span></p><p><b>comment</b>: In this example, the blood pressure measurements are not available due to cancellation of the order.  Data absent reason is present for each component</p><p><b>bodySite</b>: Right arm <span>(Details : {SNOMED CT code '368209003' = 'Right upper arm structure (body structure)', given as 'Right arm'})</span></p><blockquote><p><b>component</b></p><p><b>code</b>: Systolic blood pressure <span>(Details : {LOINC code '8480-6' = 'Systolic blood pressure', given as 'Systolic blood pressure'}; {SNOMED CT code '271649006' = 'Systolic blood pressure (observable entity)', given as 'Systolic blood pressure'}; {http://acme.org/devices/clinical-codes code 'bp-s' = '??', given as 'Systolic Blood pressure'})</span></p><p><b>dataAbsentReason</b>: Not Asked <span>(Details : {http://hl7.org/fhir/data-absent-reason code 'not-asked' = 'Not Asked', given as 'Not Asked'})</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span>(Details : {LOINC code '8462-4' = 'Diastolic blood pressure', given as 'Diastolic blood pressure'})</span></p><p><b>dataAbsentReason</b>: Not Asked <span>(Details : {http://hl7.org/fhir/data-absent-reason code 'not-asked' = 'Not Asked', given as 'Not Asked'})</span></p></blockquote></div>"
  ];
  fhir:Observation.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "urn:ietf:rfc:3986" ];
     fhir:Identifier.value [ fhir:value "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" ]
  ];
  fhir:Observation.status [ fhir:value "cancelled"];
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:concept loinc:55284-4;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "55284-4" ];
       fhir:Coding.display [ fhir:value "Blood pressure systolic & diastolic" ]
     ]
  ];
  fhir:Observation.subject [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ];
  fhir:Observation.effectiveDateTime [ fhir:value "2012-09-17"^^xsd:date];
  fhir:Observation.performer [
     fhir:index 0;
     fhir:link <http://hl7.org/fhir/Practitioner/example>;
     fhir:Reference.reference [ fhir:value "Practitioner/example" ]
  ];
  fhir:Observation.interpretation [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ];
       fhir:Coding.code [ fhir:value "L" ];
       fhir:Coding.display [ fhir:value "low" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Below low normal" ]
  ];
  fhir:Observation.comment [ fhir:value "In this example, the blood pressure measurements are not available due to cancellation of the order.  Data absent reason is present for each component"];
  fhir:Observation.bodySite [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:concept sct:368209003;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "368209003" ];
       fhir:Coding.display [ fhir:value "Right arm" ]
     ]
  ];
  fhir:Observation.component [
     fhir:index 0;
     fhir:Observation.component.code [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:concept loinc:8480-6;
         fhir:Coding.system [ fhir:value "http://loinc.org" ];
         fhir:Coding.code [ fhir:value "8480-6" ];
         fhir:Coding.display [ fhir:value "Systolic blood pressure" ]
       ], [
         fhir:index 1;
         fhir:concept sct:271649006;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "271649006" ];
         fhir:Coding.display [ fhir:value "Systolic blood pressure" ]
       ], [
         fhir:index 2;
         fhir:Coding.system [ fhir:value "http://acme.org/devices/clinical-codes" ];
         fhir:Coding.code [ fhir:value "bp-s" ];
         fhir:Coding.display [ fhir:value "Systolic Blood pressure" ]
       ]
     ];
     fhir:Observation.component.dataAbsentReason [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/data-absent-reason" ];
         fhir:Coding.code [ fhir:value "not-asked" ];
         fhir:Coding.display [ fhir:value "Not Asked" ]
       ]
     ]
  ], [
     fhir:index 1;
     fhir:Observation.component.code [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:concept loinc:8462-4;
         fhir:Coding.system [ fhir:value "http://loinc.org" ];
         fhir:Coding.code [ fhir:value "8462-4" ];
         fhir:Coding.display [ fhir:value "Diastolic blood pressure" ]
       ]
     ];
     fhir:Observation.component.dataAbsentReason [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/data-absent-reason" ];
         fhir:Coding.code [ fhir:value "not-asked" ];
         fhir:Coding.display [ fhir:value "Not Asked" ]
       ]
     ]
  ] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

<http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.