Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Do-uslab-example1.xml

Raw XML (canonical form)

USLabOrder Blood Lead (id = "do-uslab-example1")

<DiagnosticOrder xmlns="http://hl7.org/fhir">
  <id value="do-uslab-example1"/>
  <!--    comment out to see if causing build to hang extension for a CC to a non ordering party
   in this case another provider
  <extension url="http://hl7.org/fhir/StructureDefinition/uslab-cc-practitioner">
    <valueReference>
      <reference value="Practitioner/uslab-example2"/>
      <display value="Dr Bill T Lookafter Jr"/>
    </valueReference>
  </extension>
   -->
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: do-uslab-example1</p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>orderer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>identifier</b>: ORD000123A (OFFICIAL)</p><p><b>reason</b>: Abnormal lead level in blood <span>(Details : {http://www.icd10data.com/icd10pcs code 'R78.71' = '??', given as 'Abnormal
           lead level in blood'})</span></p><p><b>supportingInformation</b>: <a>Prior Results Observation</a>, <a>Lead Exposure</a></p><p><b>status</b>: requested</p><p><b>priority</b>: routine</p><h3>Events</h3><table><tr><td>-</td><td><b>Status</b></td><td><b>Description</b></td><td><b>DateTime</b></td></tr><tr><td>*</td><td>requested</td><td>new-request <span>(Details : {[not stated] code 'new-request' = '??)</span></td><td>04/12/2014 3:42:15 PM</td></tr></table><h3>Items</h3><table><tr><td>-</td><td><b>Code</b></td><td><b>Specimen</b></td><td><b>Status</b></td></tr><tr><td>*</td><td>Blood Lead <span>(Details : {LOINC code '5671-3' = 'Lead [Mass/volume] in Blood', given as 'Lead [Mass/volume]
               in Blood'}; {urn:oid:2.16.840.1.113883.3.72.5.24 code 'BLDLD' = '??', given as 'Blood
               Lead'})</span></td><td><a>Whole blood</a></td><td>requested</td></tr></table><p><b>note</b>: patient is afraid of needles</p></div></text><subject>
    <reference value="Patient/patient-uslab-example1"/>
    <display value="Todd Lerr"/>
  </subject>
  <orderer>
    <reference value="Practitioner/pract-uslab-example1"/>
    <display value="Dr Leonard T Bloodraw Jr"/>
  </orderer>
  <identifier>
    <use value="official"/>
    <!--    EH Using an OID here but could any URI  eg  http://aceclinic.com    -->
    <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/>
    <value value="ORD000123A"/>
  </identifier>
  <reason>
    <coding>
      <system value="http://www.icd10data.com/icd10pcs"/>
      <code value="R78.71"/>
      <display value="Abnormal lead level in blood"/>
    </coding>
    <text value="Abnormal lead level in blood"/>
  </reason>
  <supportingInformation>
    <reference value="Observation/obs-uslab-example1"/>
    <display value="Prior Results Observation"/>
  </supportingInformation>
  <supportingInformation>
    <reference value="Condition/cond-uslab-example1"/>
    <display value="Lead Exposure"/>
  </supportingInformation>
  <!--     EH this specimen is for when lab has existing
<specimen>
    <reference value="Specimen/uslab-example1"/>
    <display value="Whole blood"/>
  </specimen>
   -->
  <!--    EH this is set to 'requested' by the Placer   -->
  <status value="requested"/>
  <priority value="routine"/>
  <event>
    <!--    EH this is set to 'requested' by the Placer is required element in core resource   -->
    <status value="requested"/>
    <!--    EH:bound to closed value setUSLAB Diagnostic Order Event Codes   -->
    <description>
      <coding>
        <code value="new-request"/>
      </coding>
    </description>
    <!--    EH: Showing dateTime to ss with TZO although only needed to Day    -->
    <dateTime value="2014-12-04T15:42:15-08:00"/>
    <!--    EH:  the event is the order placer requesting a test   -->
  </event>
  <item>
    <!--   EH :  The local and /or LOINC test codes go here    -->
    <code>
      <!--    EH: LOINC code gos here   -->
      <coding>
        <system value="http://loinc.org"/>
        <code value="5671-3"/>
        <display value="Lead [Mass/volume] in Blood"/>
        <!--    EH: LOINC code gos here   -->
      </coding>
      <coding>
        <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/>
        <code value="BLDLD"/>
        <display value="Blood Lead"/>
      </coding>
      <text value="Blood Lead"/>
    </code>
    <specimen>
      <reference value="Specimen/spec-uslab-example1"/>
      <display value="Whole blood"/>
    </specimen>
    <!--    EH this is set to 'requested' by the Placer    -->
    <status value="requested"/>
  </item>
  <note>
    <text value="patient is afraid of needles"/>
  </note>
</DiagnosticOrder>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.