This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
The official URL for this profile is:
http://hl7.org/fhir/StructureDefinition/qicore-device
Profile of Device for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.
This profile was published on Wed, Mar 11, 2015 00:00+1100 as a draft by Health Level Seven International (Clinical Quality Information - QICore).
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Device.
This structure is derived from Device.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | An instance of a manufactured te that is used in the provision of healthcare | |
meta | ∑ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: IETF BCP-47 (required) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | Instance id from manufacturer, owner, and others | |
type | S | 1..1 | CodeableConcept | What kind of device this is Binding: ???? (preferred) |
note | 0..* | Annotation | Device notes and comments | |
status | ?! S∑ | 0..1 | code | available | not-available | entered-in-error Binding: DeviceStatus (required) |
manufacturer | 0..1 | string | Name of device manufacturer | |
model | 0..1 | string | Model id assigned by the manufacturer | |
version | 0..1 | string | Version number (i.e. software) | |
manufactureDate | 0..1 | dateTime | Manufacture date | |
expiry | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
udi | 0..1 | string | FDA mandated Unique Device Identifier | |
lotNumber | 0..1 | string | Lot number of manufacture | |
owner | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
location | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
patient | S | 0..1 | Reference(QICore-Patient) | If the resource is affixed to a person |
contact | 0..* | ContactPoint | Details for human/organization for support | |
url | 0..1 | uri | Network address to contact device | |
Documentation for this format |
todo
This structure is derived from Device.
Differential View
This structure is derived from Device.
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | An instance of a manufactured te that is used in the provision of healthcare | |
meta | ∑ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: IETF BCP-47 (required) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | Instance id from manufacturer, owner, and others | |
type | S | 1..1 | CodeableConcept | What kind of device this is Binding: ???? (preferred) |
note | 0..* | Annotation | Device notes and comments | |
status | ?! S∑ | 0..1 | code | available | not-available | entered-in-error Binding: DeviceStatus (required) |
manufacturer | 0..1 | string | Name of device manufacturer | |
model | 0..1 | string | Model id assigned by the manufacturer | |
version | 0..1 | string | Version number (i.e. software) | |
manufactureDate | 0..1 | dateTime | Manufacture date | |
expiry | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
udi | 0..1 | string | FDA mandated Unique Device Identifier | |
lotNumber | 0..1 | string | Lot number of manufacture | |
owner | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
location | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
patient | S | 0..1 | Reference(QICore-Patient) | If the resource is affixed to a person |
contact | 0..* | ContactPoint | Details for human/organization for support | |
url | 0..1 | uri | Network address to contact device | |
Documentation for this format |
XML Template
JSON Template
todo
Other representations of profile: Schematron
Path | Name | Conformance | ValueSet |
Device.language | ?ext | required | http://tools.ietf.org/html/bcp47 |
Device.type | ?ext | preferred | https://www.gmdnagency.org/Info.aspx?pageid=1091 |
Device.status | DeviceStatus | required | DeviceStatus |
Id | Path | Details | Requirements |