Mappings for the observation resource.
Observation | Observation[classCode=OBS, moodCode=EVN] |
code | code |
value[x] | value |
dataAbsentReason | value.nullFlavor |
interpretation | interpretationCode |
comments | subjectOf.observationEvent[code="annotation"].value |
applies[x] | effectiveTime |
issued | participation[typeCode=AUT].time |
status | status
Amended & Final are differentiated by whether it is the subject of a ControlAct event with a type of "revise" |
reliability | uncertaintyCode |
bodySite[x] | targetSiteCode |
method | methodCode |
identifier | id |
subject | participation[typeCode=SBJ] |
specimen | participation[typeCode=SPC].specimen |
performer | participation[typeCode=PRF] |
device | participation[typeCode=DEV] |
encounter | inboundRelationship[typeCode=COMP].source[classCode=ENC, moodCode=EVN] |
referenceRange | outboundRelationship[typeCode=REFV]/target[classCode=OBS, moodCode=EVN] |
low | value:IVL_PQ.low |
high | value:IVL_PQ.high |
meaning | interpretationCode |
age | outboundRelationship[typeCode=PRCN].targetObservationCriterion[code="age"].value |
text | value:ST |
related | outBoundRelationship |
type | .typeCode |
target | .targetObservation |
Observation | OBX |
code | OBX-3-observation identifier |
value[x] | OBX.2, OBX.5, OBX.6 |
dataAbsentReason | N/A |
interpretation | OBX-8-interpretation codes |
comments | NTE.3 (partner NTE to OBX, or sometimes another (child?) OBX) |
applies[x] | OBX-14-date/time of the observation, and/or OBX-19 after v2.4 (depends on who observation made) |
issued | OBR.22 (or MSH.7), or perhaps OBX-19 (depends on who observation made) |
status | OBX-11-observation result status |
reliability | Maybe OBX.8/OBX.9 |
bodySite[x] | OBX-20-observation site |
method | OBX-17-observation method |
identifier | OBX.21 |
subject | PID-3-patient ID list |
specimen | SPM segment |
performer | OBX.15 / (Practitioner) OBX-16-responsible observer, PRT-5-participation person:PRT-4-participation='RO' /
(Device) OBX-18-equipment instance identifier , PRT-10-participation device:PRT-4-participation='EQUIP' / (Organization) OBX-23-performing organization name, PRT-8-participation organization:PRT-4-participation='PO' |
device | OBX-17 / PRT -10 |
encounter | PV1 |
referenceRange | OBX.7 |
low | OBX-7-references range |
high | OBX-7-references range |
meaning | OBX-10-nature of abnormal test? |
age | |
text | OBX-7-references range |
related | Relationships established by OBX-4 usage |
type | N/A |
target | |