This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Detailed Descriptions for the elements in the Device resource.
Device | |
Definition | This resource identifies an instance of a manufactured thing that is used in the provision of healthcare without being substantially changed through that activity. The device may be a machine, an insert, a computer, an application, etc. This includes durable (reusable) medical equipment as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health. |
Control | 1..1 |
Requirements | Allows institutions to track their devices. |
Device.identifier | |
Definition | Unique instance identifiers assigned to a device by organizations like manufacturers or owners . If the identifier identifies the type of device, Device.type should be used. |
Note | This is a business identifer, not a resource identifier (see discussion) |
Control | 0..* |
Type | Identifier |
Comments | Often fixed to the device as a barcode and may include names given to the device in local usage. Note that some of the barcodes affixed to the device identify its type, not its instance. For the FDA Mandated Unique Device Identifier (UDI) use the Device.udi element. |
Device.type | |
Definition | Code or identifier to identify a kind of device. |
Control | 1..1 |
Binding | DeviceKind: Example: RTM Management Service (Defines the nature of the device and the kind of functionality/services/behavior that may be expected from it) |
Type | CodeableConcept |
Comments | For the FDA Mandated Unique Device Identifier (UDI) use the Device.udi element. |
Device.status | |
Definition | Status of the Device availability. |
Control | 0..1 |
Binding | DeviceStatus: Required: http://hl7.org/fhir/devicestatus (The availability status of the device) |
Type | code |
Is Modifier | true |
Summary | true |
Device.manufacturer | |
Definition | A name of the manufacturer. |
Control | 0..1 |
Type | string |
Device.model | |
Definition | The "model" - an identifier assigned by the manufacturer to identify the product by its type. This number is shared by the all devices sold as the same type. |
Control | 0..1 |
Type | string |
Device.version | |
Definition | The version of the device, if the device has multiple releases under the same model, or if the device is software or carries firmware. |
Note | This is a business versionId, not a resource identifier (see discussion) |
Control | 0..1 |
Type | string |
Device.manufactureDate | |
Definition | The Date and time when the device was manufactured. |
Control | 0..1 |
Type | dateTime |
Device.expiry | |
Definition | The date and time beyond which this device is no longer valid or should not be used (if applicable). |
Control | 0..1 |
Type | dateTime |
Device.udi | |
Definition | United States Food and Drug Administration mandated Unique Device Identifier (UDI). Use the human readable information (the content that the user sees, which is sometimes different to the exact syntax represented in the barcode) - see http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/default.htm. |
Control | 0..1 |
Type | string |
Comments | The unique identifier may identify an instance of a device uniquely, or it may just identify the type of the device. A portion of the UDI - the DI part - can be extracted from the UDI when required, and used to look up information about the device through the GUDID. |
Device.lotNumber | |
Definition | Lot number assigned by the manufacturer. |
Control | 0..1 |
Type | string |
Comments | Alphanumeric Maximum 20. |
Device.owner | |
Definition | An organization that is responsible for the provision and ongoing maintenance of the device. |
Control | 0..1 |
Type | Reference(Organization) |
Device.location | |
Definition | The resource may be found in a literal location (i.e. GPS coordinates), a logical place (i.e. "in/with the patient"), or a coded location. |
Control | 0..1 |
Type | Reference(Location) |
Device.patient | |
Definition | Patient information, if the resource is affixed to a person. |
Control | 0..1 |
Type | Reference(Patient) |
Device.contact | |
Definition | Contact details for an organization or a particular human that is responsible for the device. |
Control | 0..* |
Type | ContactPoint |
Comments | used for troubleshooting etc. |
Device.url | |
Definition | A network address on which the device may be contacted directly. |
Control | 0..1 |
Type | uri |
Comments | If the device is running a FHIR server, the network address should be the root URL from which a conformance statement may be retrieved. |