GAO Ballot Package

This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

F.9.1 StructureDefinition: QICore-DeviceUseRequest

This profile is marked as a draft.

The official URL for this profile is:

http://hl7.org/fhir/StructureDefinition/qicore-deviceuserequest

Profile of DeviceUseRequest for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.

This profile was published on Fri, Feb 27, 2015 00:00+1100 as a draft by Health Level Seven International (Clinical Quality Information - QICore).

F.9.1.1 Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.

NameFlagsCard.TypeDescription & Constraintsdoco
.. DeviceUseRequest 0..*DeviceUseRequestA request for a patient to use or be given a medical device
... meta 0..1MetaMetadata about the resource
... implicitRules ?! 0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: IETF BCP-47 (required)
... text I0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... deviceuserequest-reasonRejected 0..1CodeableConceptExtension
URL: http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected
Binding: Reasons for rejecting device use request codes (example)
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... bodySite[x] S 0..1CodeableConcept, Reference(QICore-BodySite)Target body site
Binding: SNOMED CT Body Structures (example)
... status ?! S0..1codeproposed | planned | requested | received | accepted | in-progress | completed | suspended | rejected | aborted
Binding: DeviceUseRequestStatus (required)
... device S 1..1Reference(QICore-Device)Device requested
... encounter S 0..1Reference(QICore-Encounter)Encounter motivating request
... identifier 0..*IdentifierRequest identifier
... indication 0..*CodeableConceptReason for request
Binding: Problem Value Set (preferred)
... notes 0..*stringNotes or comments
... prnReason 0..*CodeableConceptPRN
Binding: Problem Value Set (preferred)
... orderedOn S 0..1dateTimeWhen ordered
... recordedOn S 0..1dateTimeWhen recorded
... subject S 1..1Reference(QICore-Patient)Focus of request
... timing[x] 0..1Timing, Period, dateTimeSchedule for use
... priority 0..1coderoutine | urgent | stat | asap
Binding: DeviceUseRequestPriority (required)

doco Documentation for this format

todo

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. DeviceUseRequest 0..*DeviceUseRequestA request for a patient to use or be given a medical device
... meta 0..1MetaMetadata about the resource
... implicitRules ?! 0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: IETF BCP-47 (required)
... text I0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... deviceuserequest-reasonRejected 0..1CodeableConceptExtension
URL: http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected
Binding: Reasons for rejecting device use request codes (example)
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... bodySite[x] S 0..1CodeableConcept, Reference(QICore-BodySite)Target body site
Binding: SNOMED CT Body Structures (example)
... status ?! S0..1codeproposed | planned | requested | received | accepted | in-progress | completed | suspended | rejected | aborted
Binding: DeviceUseRequestStatus (required)
... device S 1..1Reference(QICore-Device)Device requested
... encounter S 0..1Reference(QICore-Encounter)Encounter motivating request
... identifier 0..*IdentifierRequest identifier
... indication 0..*CodeableConceptReason for request
Binding: Problem Value Set (preferred)
... notes 0..*stringNotes or comments
... prnReason 0..*CodeableConceptPRN
Binding: Problem Value Set (preferred)
... orderedOn S 0..1dateTimeWhen ordered
... recordedOn S 0..1dateTimeWhen recorded
... subject S 1..1Reference(QICore-Patient)Focus of request
... timing[x] 0..1Timing, Period, dateTimeSchedule for use
... priority 0..1coderoutine | urgent | stat | asap
Binding: DeviceUseRequestPriority (required)

doco Documentation for this format

XML Template

JSON Template

todo

 

Other representations of profile: Schematron

F.9.1.2 Terminology Bindings

PathNameConformanceValueSet
DeviceUseRequest.language?extrequiredhttp://tools.ietf.org/html/bcp47
DeviceUseRequest.extension
[UriType[http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected]]
Reasons for rejecting device use request codesexampleReasons for rejecting device use request codes
DeviceUseRequest.bodySite[x]SNOMED CT Body StructuresexampleSNOMED CT Body Structures
DeviceUseRequest.statusDeviceUseRequestStatusrequiredDeviceUseRequestStatus
DeviceUseRequest.indicationProblem Value SetpreferredProblem Value Set
DeviceUseRequest.prnReasonProblem Value SetpreferredProblem Value Set
DeviceUseRequest.priorityDeviceUseRequestPriorityrequiredDeviceUseRequestPriority

F.9.1.3 Constraints

IdPathDetailsRequirements
.