This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.
The official URL for this profile is:
http://hl7.org/fhir/StructureDefinition/qicore-device
Profile of Device for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.
This profile was published on Wed, Mar 11, 2015 00:00+1100 as a draft by Health Level Seven International (Clinical Quality Information - QICore).
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Device.
This structure is derived from Device.
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | An instance of a manufactured te that is used in the provision of healthcare | |
![]() ![]() ![]() | ∑ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: IETF BCP-47 ![]() | |
![]() ![]() ![]() | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() ![]() | 0..* | Extension | Additional Content defined by implementations | |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | 0..* | Identifier | Instance id from manufacturer, owner, and others | |
![]() ![]() ![]() | S | 1..1 | CodeableConcept | What kind of device this is Binding: ???? ![]() |
![]() ![]() ![]() | 0..* | Annotation | Device notes and comments | |
![]() ![]() ![]() | ?! S∑ | 0..1 | code | available | not-available | entered-in-error Binding: DeviceStatus (required) |
![]() ![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() ![]() | 0..1 | string | Model id assigned by the manufacturer | |
![]() ![]() ![]() | 0..1 | string | Version number (i.e. software) | |
![]() ![]() ![]() | 0..1 | dateTime | Manufacture date | |
![]() ![]() ![]() | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() ![]() | 0..1 | string | FDA mandated Unique Device Identifier | |
![]() ![]() ![]() | 0..1 | string | Lot number of manufacture | |
![]() ![]() ![]() | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
![]() ![]() ![]() | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
![]() ![]() ![]() | S | 0..1 | Reference(QICore-Patient) | If the resource is affixed to a person |
![]() ![]() ![]() | 0..* | ContactPoint | Details for human/organization for support | |
![]() ![]() ![]() | 0..1 | uri | Network address to contact device | |
![]() |
todo
This structure is derived from Device.
Differential View
This structure is derived from Device.
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | An instance of a manufactured te that is used in the provision of healthcare | |
![]() ![]() ![]() | ∑ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: IETF BCP-47 ![]() | |
![]() ![]() ![]() | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() ![]() | 0..* | Extension | Additional Content defined by implementations | |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | 0..* | Identifier | Instance id from manufacturer, owner, and others | |
![]() ![]() ![]() | S | 1..1 | CodeableConcept | What kind of device this is Binding: ???? ![]() |
![]() ![]() ![]() | 0..* | Annotation | Device notes and comments | |
![]() ![]() ![]() | ?! S∑ | 0..1 | code | available | not-available | entered-in-error Binding: DeviceStatus (required) |
![]() ![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() ![]() | 0..1 | string | Model id assigned by the manufacturer | |
![]() ![]() ![]() | 0..1 | string | Version number (i.e. software) | |
![]() ![]() ![]() | 0..1 | dateTime | Manufacture date | |
![]() ![]() ![]() | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() ![]() | 0..1 | string | FDA mandated Unique Device Identifier | |
![]() ![]() ![]() | 0..1 | string | Lot number of manufacture | |
![]() ![]() ![]() | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
![]() ![]() ![]() | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
![]() ![]() ![]() | S | 0..1 | Reference(QICore-Patient) | If the resource is affixed to a person |
![]() ![]() ![]() | 0..* | ContactPoint | Details for human/organization for support | |
![]() ![]() ![]() | 0..1 | uri | Network address to contact device | |
![]() |
XML Template
JSON Template
todo
Other representations of profile: Schematron
Path | Name | Conformance | ValueSet |
Device.language | ?ext | required | http://tools.ietf.org/html/bcp47 ![]() |
Device.type | ?ext | preferred | https://www.gmdnagency.org/Info.aspx?pageid=1091 ![]() |
Device.status | DeviceStatus | required | DeviceStatus |
Id | Path | Details | Requirements |