DSTU2

This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-unsat.xml

Raw XML (canonical form)

Specimen Reject Example (id = "unsat")

<Observation xmlns="http://hl7.org/fhir">
  <id value="unsat"/>
<!--     urn:oid:2.16.840.1.113883.4.642.1.7     -->
<!--     2.16.840.1.113883.4.642.1.118     -->
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: unsat</p><p><b>identifier</b>: 6323 (OFFICIAL)</p><p><b>status</b>: cancelled</p><p><b>code</b>: Glucose [Moles/volume] in Blood <span>(Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose
           [Moles/volume] in Blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 9:30:10 AM --&gt; 05/04/2013 9:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>dataAbsentReason</b>: Specimen unsatisfactory for evaluation <span>(Details : {SNOMED CT code '125154007' = '125154007', given as 'Specimen unsatisfactory
           for evaluation'})</span></p><p><b>comments</b>: Tube broken in transit and sample leaked</p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>3.1 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = '??')</span></td><td>6.2 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = '??')</span></td></tr></table></div></text><identifier>
    <use value="official"/>
    <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/>
    <value value="6323"/>
  </identifier>
  <status value="cancelled"/>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="15074-8"/>
      <display value="Glucose [Moles/volume] in Blood"/>
    </coding>
  </code>
  <subject>
    <reference value="Patient/f001"/>
    <display value="P. van de Heuvel"/>
  </subject>
  <effectivePeriod>
    <start value="2013-04-02T09:30:10+01:00"/>
    <end value="2013-04-05T09:30:10+01:00"/>
  </effectivePeriod>
  <issued value="2013-04-03T15:30:10+01:00"/>
  <performer>
    <reference value="Practitioner/f005"/>
    <display value="A. Langeveld"/>
  </performer>
  <dataAbsentReason>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="125154007"/>
      <display value="Specimen unsatisfactory for evaluation"/>
    </coding>
  </dataAbsentReason>
  <comments value="Tube broken in transit and sample leaked"/>
  <referenceRange>
    <low>
      <value value="3.1"/>
      <unit value="mmol/l"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="mmol/L"/>
    </low>
    <high>
      <value value="6.2"/>
      <unit value="mmol/l"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="mmol/L"/>
    </high>
  </referenceRange>
</Observation>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.