This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Real-world patient - creatinine (id = "f204")
<Observation xmlns="http://hl7.org/fhir"> <id value="f204"/> <!-- The observation is complete --> <!-- No reliability concerns --> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f204</p><p><b>identifier</b>: 1304-03720-Creatinine</p><p><b>status</b>: final</p><p><b>code</b>: Creatinine(Serum) <span>(Details : {https://intranet.aumc.nl/labtestcodes code '20005' = '??', given as 'Creatinine(Serum)'} )</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>issued</b>: 04/04/2013 2:34:00 PM</p><p><b>performer</b>: <a>Luigi Maas</a></p><p><b>value</b>: 122 umol/L<span> (Details: SNOMED CT code 258814008 = '258814008')</span></p><p><b>interpretation</b>: Serum creatinine raised <span>(Details : {SNOMED CT code '166717003' = '166717003', given as 'Serum creatinine raised'}; {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td><td><b>Meaning</b></td></tr><tr><td>*</td><td>64</td><td>104</td><td>Normal Range <span>(Details : {http://hl7.org/fhir/referencerange-meaning code 'normal' = 'Normal Range', given as 'Normal Range'})</span></td></tr></table></div></text><identifier> <system value="https://intranet.aumc.nl/labvalues"/> <!-- Does not exist --> <value value="1304-03720-Creatinine"/> </identifier> <!-- Creatinine was measured on April fourth --> <status value="final"/> <code> <!-- Kind of observation = Serum Creatinine, Using only a local code in this example --> <coding> <system value="https://intranet.aumc.nl/labtestcodes"/> <!-- Does not exist --> <code value="20005"/> <display value="Creatinine(Serum)"/> </coding> </code> <subject> <reference value="Patient/f201"/> <display value="Roel"/> </subject> <issued value="2013-04-04T14:34:00+01:00"/> <performer> <reference value="Practitioner/f202"/> <display value="Luigi Maas"/> </performer> <valueQuantity> <!-- Creatinine=122mmol/L --> <value value="122"/> <unit value="umol/L"/> <system value="http://snomed.info/sct"/> <code value="258814008"/> </valueQuantity> <interpretation> <coding> <system value="http://snomed.info/sct"/> <code value="166717003"/> <display value="Serum creatinine raised"/> </coding> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="H"/> </coding> </interpretation> <referenceRange> <!-- Healthy creatinine level ranges from 64umol/L to 104umol/L --> <low> <value value="64"/> </low> <high> <value value="104"/> </high> <meaning> <coding> <system value="http://hl7.org/fhir/referencerange-meaning"/> <code value="normal"/> <display value="Normal Range"/> </coding> </meaning> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.