This page is part of the FHIR Specification (v0.4.0: DSTU 2 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
FHIR Value set/code system definition for HL7 v2 table 0076 ( Message Type)
{ "resourceType": "ValueSet", "id": "v2-0076", "meta": { "profile": [ "http://hl7.org/fhir/Profile/valueset-shareable-definition" ] }, "text": { "status": "additional", "div": "<div>!-- Snipped for Brevity --></div>" }, "url": "http://hl7.org/fhir/v2/vs/0076", "version": "2.7", "name": "v2 Message Type", "publisher": "HL7, Inc", "contact": [ { "telecom": [ { "system": "url", "value": "http://hl7.org" } ] } ], "description": "FHIR Value set/code system definition for HL7 v2 table 0076 ( Message Type)", "status": "active", "experimental": true, "date": "2011-01-28", "define": { "system": "http://hl7.org/fhir/v2/0076", "caseSensitive": true, "concept": [ { "code": "ACK", "display": "General acknowledgment message" }, { "code": "ADR", "display": "ADT response" }, { "code": "ADT", "display": "ADT message" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "ARD", "display": "Ancillary RPT (display) (for backward compatibility only)" }, { "code": "BAR", "display": "Add/change billing account" }, { "code": "BPS", "display": "Blood product dispense status message" }, { "code": "BRP", "display": "Blood product dispense status acknowledgement message" }, { "code": "BRT", "display": "Blood product transfusion/disposition acknowledgement message" }, { "code": "BTS", "display": "Blood product transfusion/disposition message" }, { "code": "CCF", "display": "Collaborative Care Fetch" }, { "code": "CCI", "display": "Collaborative Care Information" }, { "code": "CCM", "display": "Collaborative Care Message" }, { "code": "CCQ", "display": "Collaborative Care Referral" }, { "code": "CCU", "display": "Collaborative Care Referral" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "CNQ", "display": "Cancel query" }, { "code": "CQU", "display": "Collaborative Care Referral" }, { "code": "CRM", "display": "Clinical study registration message" }, { "code": "CSU", "display": "Unsolicited study data message" }, { "code": "DFT", "display": "Detail financial transactions" }, { "code": "DOC", "display": "Document response" }, { "code": "DSR", "display": "Display response" }, { "code": "EAC", "display": "Automated equipment command message" }, { "code": "EAN", "display": "Automated equipment notification message" }, { "code": "EAR", "display": "Automated equipment response message" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "EDR", "display": "Enhanced display response" }, { "code": "EHC", "display": "Health Care Invoice" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "EQQ", "display": "Embedded query language query" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "ERP", "display": "Event replay response" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "ERQ", "display": "Event replay query" }, { "code": "ESR", "display": "Automated equipment status update acknowledgment message" }, { "code": "ESU", "display": "Automated equipment status update message" }, { "code": "INR", "display": "Automated equipment inventory request message" }, { "code": "INU", "display": "Automated equipment inventory update message" }, { "code": "LSR", "display": "Automated equipment log/service request message" }, { "code": "LSU", "display": "Automated equipment log/service update message" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "MCF", "display": "Delayed Acknowledgment (Retained for backward compatibility only)" }, { "code": "MDM", "display": "Medical document management" }, { "code": "MFD", "display": "Master files delayed application acknowledgment" }, { "code": "MFK", "display": "Master files application acknowledgment" }, { "code": "MFN", "display": "Master files notification" }, { "code": "MFQ", "display": "Master files query" }, { "code": "MFR", "display": "Master files response" }, { "code": "NMD", "display": "Application management data message" }, { "code": "NMQ", "display": "Application management query message" }, { "code": "NMR", "display": "Application management response message" }, { "code": "OMB", "display": "Blood product order message" }, { "code": "OMD", "display": "Dietary order" }, { "code": "OMG", "display": "General clinical order message" }, { "code": "OMI", "display": "Imaging order" }, { "code": "OML", "display": "Laboratory order message" }, { "code": "OMN", "display": "Non-stock requisition order message" }, { "code": "OMP", "display": "Pharmacy/treatment order message" }, { "code": "OMS", "display": "Stock requisition order message" }, { "code": "OPL", "display": "Population/Location-Based Laboratory Order Message" }, { "code": "OPR", "display": "Population/Location-Based Laboratory Order Acknowledgment Message" }, { "code": "OPU", "display": "Unsolicited Population/Location-Based Laboratory Observation Message" }, { "code": "ORA", "display": "Observation Report Acknowledgment" }, { "code": "ORB", "display": "Blood product order acknowledgement message" }, { "code": "ORD", "display": "Dietary order acknowledgment message" }, { "code": "ORF", "display": "Query for results of observation" }, { "code": "ORG", "display": "General clinical order acknowledgment message" }, { "code": "ORI", "display": "Imaging order acknowledgement message" }, { "code": "ORL", "display": "Laboratory acknowledgment message (unsolicited)" }, { "code": "ORM", "display": "Pharmacy/treatment order message" }, { "code": "ORN", "display": "Non-stock requisition - General order acknowledgment message" }, { "code": "ORP", "display": "Pharmacy/treatment order acknowledgment message" }, { "code": "ORR", "display": "General order response message response to any ORM" }, { "code": "ORS", "display": "Stock requisition - Order acknowledgment message" }, { "code": "ORU", "display": "Unsolicited transmission of an observation message" }, { "code": "OSM", "display": "Specimen Shipment Message" }, { "code": "OSQ", "display": "Query response for order status" }, { "code": "OSR", "display": "Query response for order status" }, { "code": "OUL", "display": "Unsolicited laboratory observation message" }, { "code": "PEX", "display": "Product experience message" }, { "code": "PGL", "display": "Patient goal message" }, { "code": "PIN", "display": "Patient insurance information" }, { "code": "PMU", "display": "Add personnel record" }, { "code": "PPG", "display": "Patient pathway message (goal-oriented)" }, { "code": "PPP", "display": "Patient pathway message (problem-oriented)" }, { "code": "PPR", "display": "Patient problem message" }, { "code": "PPT", "display": "Patient pathway goal-oriented response" }, { "code": "PPV", "display": "Patient goal response" }, { "code": "PRR", "display": "Patient problem response" }, { "code": "PTR", "display": "Patient pathway problem-oriented response" }, { "code": "QBP", "display": "Query by parameter" }, { "code": "QCK", "display": "Deferred query" }, { "code": "QCN", "display": "Cancel query" }, { "code": "QRY", "display": "Query, original mode" }, { "code": "QSB", "display": "Create subscription" }, { "code": "QSX", "display": "Cancel subscription/acknowledge message" }, { "code": "QVR", "display": "Query for previous events" }, { "code": "RAR", "display": "Pharmacy/treatment administration information" }, { "code": "RAS", "display": "Pharmacy/treatment administration message" }, { "code": "RCI", "display": "Return clinical information" }, { "code": "RCL", "display": "Return clinical list" }, { "code": "RDE", "display": "Pharmacy/treatment encoded order message" }, { "code": "RDR", "display": "Pharmacy/treatment dispense information" }, { "code": "RDS", "display": "Pharmacy/treatment dispense message" }, { "code": "RDY", "display": "Display based response" }, { "code": "REF", "display": "Patient referral" }, { "code": "RER", "display": "Pharmacy/treatment encoded order information" }, { "code": "RGR", "display": "Pharmacy/treatment dose information" }, { "code": "RGV", "display": "Pharmacy/treatment give message" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "ROC", "display": "Request clinical information" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "ROD", "display": "Request pateint demographics" }, { "code": "ROR", "display": "Pharmacy/treatment order response" }, { "code": "RPA", "display": "Return patient authorization" }, { "code": "RPI", "display": "Return patient information" }, { "code": "RPL", "display": "Return patient display list" }, { "code": "RPR", "display": "Return patient list" }, { "code": "RQA", "display": "Request patient authorization" }, { "code": "RQC", "display": "Request clinical information" }, { "code": "RQI", "display": "Request patient information" }, { "code": "RQP", "display": "Request patient demographics" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "RQQ", "display": "Event replay query" }, { "code": "RRA", "display": "Pharmacy/treatment administration acknowledgment message" }, { "code": "RRD", "display": "Pharmacy/treatment dispense acknowledgment message" }, { "code": "RRE", "display": "Pharmacy/treatment encoded order acknowledgment message" }, { "code": "RRG", "display": "Pharmacy/treatment give acknowledgment message" }, { "code": "RRI", "display": "Return referral information" }, { "code": "RSP", "display": "Segment pattern response" }, { "code": "RTB", "display": "Tabular response" }, { "code": "SCN", "display": "Notification of Anti-Microbial Device Cycle Data" }, { "code": "SDN", "display": "Notification of Anti-Microbial Device Data" }, { "code": "SDR", "display": "Sterilization anti-microbial device data request" }, { "code": "SIU", "display": "Schedule information unsolicited" }, { "code": "SLN", "display": "Notification of New Sterilization Lot" }, { "code": "SLR", "display": "Sterilization lot request" }, { "code": "SMD", "display": "Sterilization anti-microbial device cycle data request" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "SPQ", "display": "Stored procedure request" }, { "code": "SQM", "display": "Schedule query message" }, { "code": "SQR", "display": "Schedule query response" }, { "code": "SRM", "display": "Schedule request message" }, { "code": "SRR", "display": "Scheduled request response" }, { "code": "SSR", "display": "Specimen status request message" }, { "code": "SSU", "display": "Specimen status update message" }, { "code": "STC", "display": "Notification of Sterilization Configuration" }, { "code": "STI", "display": "Sterilization item request" }, { "code": "SUR", "display": "Summary product experience report" }, { "code": "TBR", "display": "Tabular data response" }, { "code": "TCR", "display": "Automated equipment test code settings request message" }, { "code": "TCU", "display": "Automated equipment test code settings update message" }, { "code": "UDM", "display": "Unsolicited display update message" }, { "extension": [ { "url": "http://hl7.org/fhir/ExtensionDefinition/valueset-deprecated", "valueBoolean": true } ], "code": "VQQ", "display": "Virtual table query" }, { "code": "VXQ", "display": "Query for vaccination record" }, { "code": "VXR", "display": "Vaccination record response" }, { "code": "VXU", "display": "Unsolicited vaccination record update" }, { "code": "VXX", "display": "Response for vaccination query with multiple PID matches" } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.