This page is part of the FHIR Specification (v0.4.0: DSTU 2 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Fast Healthcare Interoperability Resources (FHIR) is not a security protocol, nor does it define any security related functionality. However FHIR does define exchange protocols and content models that need to be used with various security protocols defined elsewhere. This section gathers all information about security in one section. A summary:
Time critical concerns regarding security flaws in the FHIR specification should be addressed to the FHIR email list for prompt consideration. Alternatively, issues can be raised through the community input mechanism.
Implementers should track the developing IHE IUA Profile for additional security considerations.
A production FHIR system will need some kind of security sub-system that administers users, user authentication and user-authorization. Where this sub-system fits into the deployment architecture is a matter for system design:
|
In this diagram, the red lines represent FHIR interfaces. From the perspective of the FHIR API, the client (consumer of FHIR services) may either interact with a security system that manifests as a FHIR server, and which depends on a subsequent FHIR interface to provide the actual storage, or either the client or server interacts with the security system independently. In each of these 3 scenarios, the different components may be assembled into applications or network components differently, but the same logical layout applies. The FHIR specification assumes that a security system exists, and that it may be deployed in front of or behind the FHIR API.
The security system includes the following subsystems:
Because there are a plethora of standards relating to the administration and functionality of the security system, FHIR does not provide user, profile, or other such administration resources. Instead, the FHIR resources are the targets of the policies expressed in these other approaches. What FHIR does specify is a way to apply security labels to resources so that a security system may use these (along with the contents of the resources if appropriate) to determine whether a user is authorized to perform a particular FHIR operation or not.
For the RESTful API, normal HTTP security rules apply. The Service Root URL will specify whether SSL is required. Client authentication may be required by the server, possibly including the requirement for client certificates.
SSL SHOULD be used for all production data exchange.
To support browser-based client applications, recommend that servers SHOULD implement cross-origin resource sharing for the REST operations.
Other than testing systems, FHIR servers should authenticate the clients. The server may choose to authenticate the client system and trust it, or to authenticate the individual user by a variety of techniques. For web-centric use, OAuth may be used to authenticate and/or authorize the users.
Correctly identifying people, devices, locations and organizations is one of the foundations that any security system is built on. Most applications of security protocols, whether authentication, access control, digital signatures, etc. rely on the correct mapping between the relevant resources and the underlying systems. Note that this isn't necessary: there is nothing in FHIR that requires or relies on any security being in place, or any particular implementation. But real world usage will generally require this.
A holder of data should not allow the data to be communicated unless there is assurances that the other party is authorized to receive it. This is true for a Client creating a resource through a PUT/POST, as much as it is true for a Server returning resources on a GET. The presumption is that without proper authorization, to the satisfaction of the data holder, the data does not get communicated.
The rules behind the Access Control decision are often very complex, and potentially depends on information sourced from:
For one source of further information, see the IHE Access Control white paper
FHIR provides a SecurityEvent resource suitable for use by FHIR clients and servers to record when a security or privacy relevant event has occurred. This form of audit logging records as much detail as reasonable at the time the event happened.
The SecurityEvent when used to record security and privacy relevant events can then be used by properly authorized applications to support audit reporting, alerting, filtering, and forwarding. This model has been developed and used in healthcare for a decade as IHE-ATNA profile. ATNA log events can be automatically converted to SecurityEvent resources, and from there, client applications are able to search the security events, or subscribe to them.
This specification recommends the use of W3C Digital Signatures for signatures.
Resources can be signed using the Provenance resource to carry a detached digital signature for the purpose of detecting subsequent changes to the resource. This signature is not suitable for non-repudiation purposes.
In addition, documents may be signed using an enveloped signature.
Neither of these definitions prohibits the use of other ways of using digital signatures.
DSTU Note: Additional work is anticipated in this area, including alignment with the IHE DSG profile.
Several FHIR resources include attachments. Attachments can either be references to content found elsewhere, or included inline encoded in base64. Attachments represent security risks in a way that FHIR resources do not, since some attachments contain executable code. Implementers should always use caution when handling resources.
See Security Labels.
FHIR resources include an XHTML narrative, so that applications can display the contents of the resource to users without having to fully and correctly process the data in the resource. However displaying HTML is associated with several known security issues that have been observed in production systems in other contexts (e.g. with CDA). For this reason, the FHIR narrative is not allowed to contain active content. However, care is still needed when displaying the narrative:
Also note that the inclusion of an external reference to an image can allow the server that hosts the image to track when the resource is displayed. This may be a feature or a problem depending on the context.