This page is part of the FHIR Specification (v0.4.0: DSTU 2 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Login example
{ "resourceType": "SecurityEvent", "id": "example-login", "event": { "type": { "coding": [ { "system": "http://nema.org/dicom/dicm", "code": "110114", "display": "User Authentication" } ] }, "subtype": [ { "coding": [ { "system": "http://nema.org/dicom/dicm", "code": "110122", "display": "Login" } ] } ], "action": "E", "dateTime": "2013-06-20T23:41:23Z", "outcome": "0" }, "participant": [ { "userId": "95", "altId": "601847123", "name": "Grahame Grieve", "requestor": true, "network": { "identifier": "127.0.0.1", "type": "2" } } ], "source": { "site": "Cloud", "identifier": "hl7connect.healthintersections.com.au", "type": [ { "system": "http://hl7.org/fhir/security-source-type", "code": "3", "display": "Web Server" } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.