This page is part of the FHIR Specification (v0.4.0: DSTU 2 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Generated Questionnaire for Device
{ "resourceType": "Questionnaire", "id": "qs1", "identifier": [ { "system": "urn:ietf:rfc:3986" } ], "status": "draft", "date": "2015-02-23T09:07:27+11:00", "publisher": "HL7 FHIR Project (Orders and Observations)", "group": { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "This resource identifies an instance of a manufactured thing that is used in the provision of healthcare without being substantially changed through that activity. The device may be a machine, an insert, a computer, an application, etc. This includes durable (reusable) medical equipment as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health." } ], "linkId": "Device", "title": "An instance of a manufactured thing that is used in the provision of healthcare", "required": true, "repeats": false, "group": [ { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The logical id of the resource, as used in the url for the resoure. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. Bundles always have an id, though it is usually a generated UUID." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "string" } ], "linkId": "Device.id", "required": false, "repeats": true, "question": [ { "linkId": "Device.id.value", "text": "Logical id of this artefact", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content may not always be associated with version changes to the resource." } ], "linkId": "Device.meta", "text": "Metadata about the resource", "required": false, "repeats": true }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "uri" } ], "linkId": "Device.implicitRules", "required": false, "repeats": true, "question": [ { "linkId": "Device.implicitRules.value", "text": "A set of rules under which this content was created", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The base language in which the resource is written. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource\n\nNot all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "code" } ], "linkId": "Device.language", "required": false, "repeats": true, "question": [ { "linkId": "Device.language.value", "text": "language", "type": "choice", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "A human-readable narrative that contains a summary of the resource, and may be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it \"clinically safe\" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative." } ], "linkId": "Device.text", "text": "Text summary of the resource, for human interpretation", "required": false, "repeats": true }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again." } ], "linkId": "Device.contained", "text": "Contained, inline Resources", "required": false, "repeats": true }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "Unique instance identifiers assigned to a device by organizations like manufacturers, owners or regulatory agencies. If the identifier identifies the type of device, Device.type should be used. An example is the FDA Mandated Unique Device Identifier (UDI) which identifies an instance of a device uniquely if the serial number is present, . - see http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/default.htm. Often fixed to the device as a barcode and may include names given to the device in local usage. Note that some of the barcodes affixed to the device identify its type, not its instance." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "Identifier" } ], "linkId": "Device.identifier", "text": "Instance id from manufacturer, owner, regulatory agencies and others", "required": false, "repeats": true, "question": [ { "linkId": "Device.identifier.label", "text": "label:", "type": "string", "required": false, "repeats": false }, { "linkId": "Device.identifier.system", "text": "system:", "type": "string", "required": false, "repeats": false }, { "linkId": "Device.identifier.value", "text": "value:", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "Code or identifier to identify a kind of device An example is the FDA Mandated Unique Device Identifier (UDI) which identifies a type of a device when the serial number is absent, otherwise it uniquely identifies the device instance and Device.identifier should be used instead of Device.type. - see http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/default.htm." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "CodeableConcept" } ], "linkId": "Device.type", "text": "What kind of device this is", "required": true, "repeats": true, "question": [ { "linkId": "Device.type.coding", "text": "code:", "type": "open-choice", "required": false, "repeats": false }, { "linkId": "Device.type.text", "text": "text:", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "A name of the manufacturer." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "string" } ], "linkId": "Device.manufacturer", "required": false, "repeats": true, "question": [ { "linkId": "Device.manufacturer.value", "text": "Name of device manufacturer", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The \"model\" - an identifier assigned by the manufacturer to identify the product by its type. This number is shared by the all devices sold as the same type." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "string" } ], "linkId": "Device.model", "required": false, "repeats": true, "question": [ { "linkId": "Device.model.value", "text": "Model id assigned by the manufacturer", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The version of the device, if the device has multiple releases under the same model, or if the device is software or carries firmware." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "string" } ], "linkId": "Device.version", "required": false, "repeats": true, "question": [ { "linkId": "Device.version.value", "text": "Version number (i.e. software)", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The Date and time when the device was manufactured." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "datetime" } ], "linkId": "Device.manufactureDate", "required": false, "repeats": true, "question": [ { "linkId": "Device.manufactureDate.value", "text": "Manufacture date", "type": "dateTime", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The date and time beyond which this device is no longer valid or should not be used (if applicable)." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "datetime" } ], "linkId": "Device.expiry", "required": false, "repeats": true, "question": [ { "linkId": "Device.expiry.value", "text": "Date and time of expiry of this device (if applicable)", "type": "dateTime", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "Lot number assigned by the manufacturer. Alphanumeric Maximum 20." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "string" } ], "linkId": "Device.lotNumber", "required": false, "repeats": true, "question": [ { "linkId": "Device.lotNumber.value", "text": "Lot number of manufacture", "type": "string", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "An organization that is responsible for the provision and ongoing maintenance of the device." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "Reference" } ], "linkId": "Device.owner", "required": false, "repeats": true, "question": [ { "extension": [ { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#reference", "valueString": "/Organization?subject=$subj&patient=$subj&encounter=$encounter" } ], "linkId": "Device.owner.value", "text": "Organization responsible for device", "type": "reference", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "The resource may be found in a literal location (i.e. GPS coordinates), a logical place (i.e. \"in/with the patient\"), or a coded location." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "Reference" } ], "linkId": "Device.location", "required": false, "repeats": true, "question": [ { "extension": [ { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#reference", "valueString": "/Location?subject=$subj&patient=$subj&encounter=$encounter" } ], "linkId": "Device.location.value", "text": "Where the resource is found", "type": "reference", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "Patient information, if the resource is affixed to a person." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "Reference" } ], "linkId": "Device.patient", "required": false, "repeats": true, "question": [ { "extension": [ { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#reference", "valueString": "/Patient?subject=$subj&patient=$subj&encounter=$encounter" } ], "linkId": "Device.patient.value", "text": "If the resource is affixed to a person", "type": "reference", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "Contact details for an organization or a particular human that is responsible for the device. used for troubleshooting etc." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "ContactPoint" } ], "linkId": "Device.contact", "text": "Details for human/organization for support", "required": false, "repeats": true, "question": [ { "linkId": "Device.contact.system", "text": "type:", "type": "choice", "required": false, "repeats": false }, { "linkId": "Device.contact.value", "text": "value:", "type": "string", "required": false, "repeats": false }, { "linkId": "Device.contact.use", "text": "use:", "type": "choice", "required": false, "repeats": false } ] }, { "extension": [ { "url": "http://hl7.org/fhir/Profile/questionnaire-extensions#flyover", "valueString": "A network address on which the device may be contacted directly. If the device is running a FHIR server, the network address should be the root URL from which a conformance statement may be retrieved." }, { "url": "http://www.healthintersections.com.au/fhir/Profile/metadata#type", "valueString": "uri" } ], "linkId": "Device.url", "required": false, "repeats": true, "question": [ { "linkId": "Device.url.value", "text": "Network address to contact device", "type": "string", "required": false, "repeats": false } ] } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.