FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions
| Page standards status: Informative | Maturity Level: 0 | 
{
  "resourceType" : "ValueSet",
  "id" : "R5-v3-ObservationSeriesType-for-R4",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet R5-v3-ObservationSeriesType-for-R4</b></p><a name=\"R5-v3-ObservationSeriesType-for-R4\"> </a><a name=\"hcR5-v3-ObservationSeriesType-for-R4\"> </a><p>This value set expansion contains 2 concepts.</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>System</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style=\"white-space:nowrap\"><a name=\"R5-v3-ObservationSeriesType-for-R4-http://terminology.hl7.org/CodeSystem/v3-ActCode-REPRESENTATIVE_BEAT\"> </a>\u00a0\u00a0<a href=\"http://terminology.hl7.org/6.5.0/CodeSystem-v3-ActCode.html#v3-ActCode-REPRESENTATIVE_BEAT\">REPRESENTATIVE_BEAT</a></td><td>http://terminology.hl7.org/CodeSystem/v3-ActCode</td><td>ECG representative beat waveforms</td><td><div><p>This Observation Series type contains waveforms of a "representative beat" (a.k.a. "median beat" or "average beat"). The waveform samples are measured in relative time, relative to the beginning of the beat as defined by the Observation Series effective time. The waveforms are not directly acquired from the subject, but rather algorithmically derived from the "rhythm" waveforms.</p>\n</div></td></tr><tr><td style=\"white-space:nowrap\"><a name=\"R5-v3-ObservationSeriesType-for-R4-http://terminology.hl7.org/CodeSystem/v3-ActCode-RHYTHM\"> </a>\u00a0\u00a0<a href=\"http://terminology.hl7.org/6.5.0/CodeSystem-v3-ActCode.html#v3-ActCode-RHYTHM\">RHYTHM</a></td><td>http://terminology.hl7.org/CodeSystem/v3-ActCode</td><td>ECG rhythm waveforms</td><td><div><p>This Observation type contains ECG "rhythm" waveforms. The waveform samples are measured in absolute time (a.k.a. "subject time" or "effective time"). These waveforms are usually "raw" with some minimal amount of noise reduction and baseline filtering applied.</p>\n</div></td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "fhir"
    },
    {
      "extension" : [
        {
          "url" : "packageId",
          "valueId" : "hl7.fhir.uv.xver-r5.r4"
        },
        {
          "url" : "version",
          "valueString" : "0.0.1-snapshot-2"
        }
      ],
      "url" : "http://hl7.org/fhir/StructureDefinition/package-source"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger" : 0,
      "_valueInteger" : {
        "extension" : [
          {
            "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical" : "http://hl7.org/fhir/5.0/ImplementationGuide/hl7.fhir.uv.xver-r5.r4"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode" : "informative",
      "_valueCode" : {
        "extension" : [
          {
            "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical" : "http://hl7.org/fhir/5.0/ImplementationGuide/hl7.fhir.uv.xver-r5.r4"
          }
        ]
      }
    }
  ],
  "url" : "http://hl7.org/fhir/5.0/ValueSet/R5-v3-ObservationSeriesType-for-R4",
  "version" : "0.0.1-snapshot-2",
  "name" : "R5_v3_ObservationSeriesType_for_R4",
  "title" : "Cross-version VS for R5.ObservationSeriesType for use in FHIR R4",
  "status" : "active",
  "experimental" : false,
  "date" : "2025-09-01T22:37:05.255429+10:00",
  "publisher" : "FHIR Infrastructure",
  "contact" : [
    {
      "name" : "FHIR Infrastructure",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description" : "This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v3-ObservationSeriesType|2.0.0 for use in FHIR R4. Concepts not present here have direct `equivalent` mappings crossing all versions from R5 to R4.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "compose" : {
    "include" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/v3-ActCode",
        "version" : "8.0.0",
        "concept" : [
          {
            "code" : "REPRESENTATIVE_BEAT",
            "display" : "ECG representative beat waveforms"
          },
          {
            "code" : "RHYTHM",
            "display" : "ECG rhythm waveforms"
          }
        ]
      }
    ]
  },
  "expansion" : {
    "timestamp" : "2025-09-01T22:37:05.255427+10:00",
    "contains" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/v3-ActCode",
        "version" : "8.0.0",
        "code" : "REPRESENTATIVE_BEAT",
        "display" : "ECG representative beat waveforms"
      },
      {
        "system" : "http://terminology.hl7.org/CodeSystem/v3-ActCode",
        "version" : "8.0.0",
        "code" : "RHYTHM",
        "display" : "ECG rhythm waveforms"
      }
    ]
  }
}