FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5
0.0.1-snapshot-2 - informative International flag

FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions

ValueSet: Cross-version VS for R5.ObservationInterpretationExceptions for use in FHIR R4

Official URL: http://hl7.org/fhir/5.0/ValueSet/R5-v3-ObservationInterpretationExceptions-for-R4 Version: 0.0.1-snapshot-2
Standards status: Informative Maturity Level: 0 Computable Name: R5_v3_ObservationInterpretationExceptions_for_R4

This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationExceptions 2.0.0 for use in FHIR R4. Concepts not present here have direct equivalent mappings crossing all versions from R5 to R4.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation version 2.1.0
    CodeDisplayDefinition
    <Off scale lowThe result is below the minimum detection limit (the test procedure or equipment is the limiting factor).

    Synonyms: Below analytical limit, low off scale.
    >Off scale highThe result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor).

    Synonyms: Above analytical limit, high off scale.
    ACAnti-complementary substances presentA valid result cannot be obtained for the specified component / analyte due to the presence of anti-complementary substances in the sample.

    ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.
    IEInsufficient evidenceThere is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible.

    \[Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S, I or R-categorization).\]
    QCFQuality control failureA result cannot be considered valid for the specified component / analyte or organism due to failure in the quality control testing component.

    ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.
    TOXCytotoxic substance presentA valid result cannot be obtained for the specified organism or cell line due to the presence of cytotoxic substances in the sample or culture.

    ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.

 

Expansion

This value set expansion contains 6 concepts.

CodeSystemDisplayDefinition
  <http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationOff scale low

The result is below the minimum detection limit (the test procedure or equipment is the limiting factor).

Synonyms: Below analytical limit, low off scale.

  >http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationOff scale high

The result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor).

Synonyms: Above analytical limit, high off scale.

  AChttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationAnti-complementary substances present

A valid result cannot be obtained for the specified component / analyte due to the presence of anti-complementary substances in the sample.

Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.

  IEhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationInsufficient evidence

There is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible.

[Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S, I or R-categorization).]

  QCFhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationQuality control failure

A result cannot be considered valid for the specified component / analyte or organism due to failure in the quality control testing component.

Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.

  TOXhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationCytotoxic substance present

A valid result cannot be obtained for the specified organism or cell line due to the presence of cytotoxic substances in the sample or culture.

Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code