FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions
Official URL: http://hl7.org/fhir/5.0/ValueSet/R5-v3-ObservationInterpretationExceptions-for-R4 | Version: 0.0.1-snapshot-2 | |||
Standards status: Informative | Maturity Level: 0 | Computable Name: R5_v3_ObservationInterpretationExceptions_for_R4 |
This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationExceptions | 2.0.0 for use in FHIR R4. Concepts not present here have direct equivalent mappings crossing all versions from R5 to R4. |
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
version 2.1.0
Code | Display | Definition |
< | Off scale low | The result is below the minimum detection limit (the test procedure or equipment is the limiting factor). Synonyms: Below analytical limit, low off scale. |
> | Off scale high | The result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor). Synonyms: Above analytical limit, high off scale. |
AC | Anti-complementary substances present | A valid result cannot be obtained for the specified component / analyte due to the presence of anti-complementary substances in the sample. ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes. |
IE | Insufficient evidence | There is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible. \[Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S, I or R-categorization).\] |
QCF | Quality control failure | A result cannot be considered valid for the specified component / analyte or organism due to failure in the quality control testing component. ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes. |
TOX | Cytotoxic substance present | A valid result cannot be obtained for the specified organism or cell line due to the presence of cytotoxic substances in the sample or culture. ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes. |
This value set expansion contains 6 concepts.
Code | System | Display | Definition |
< | http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation | Off scale low | The result is below the minimum detection limit (the test procedure or equipment is the limiting factor). Synonyms: Below analytical limit, low off scale. |
> | http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation | Off scale high | The result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor). Synonyms: Above analytical limit, high off scale. |
AC | http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation | Anti-complementary substances present | A valid result cannot be obtained for the specified component / analyte due to the presence of anti-complementary substances in the sample. Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes. |
IE | http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation | Insufficient evidence | There is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible. [Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S, I or R-categorization).] |
QCF | http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation | Quality control failure | A result cannot be considered valid for the specified component / analyte or organism due to failure in the quality control testing component. Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes. |
TOX | http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation | Cytotoxic substance present | A valid result cannot be obtained for the specified organism or cell line due to the presence of cytotoxic substances in the sample or culture. Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes. |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |