FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5
0.0.1-snapshot-2 - informative International flag

FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions

ValueSet: Cross-version VS for R5.Hl7VSMessageErrorConditionCodes for use in FHIR R4

Official URL: http://hl7.org/fhir/5.0/ValueSet/R5-v2-0357-for-R4 Version: 0.0.1-snapshot-2
Standards status: Informative Maturity Level: 0 Computable Name: R5_v2_0357_for_R4

This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v2-0357 2.0.0 for use in FHIR R4. Concepts not present here have direct equivalent mappings crossing all versions from R5 to R4.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v2-0357 version 2.2.0
    CodeDisplayDefinition
    0Message acceptedMessage accepted
    100Segment sequence errorSegment sequence error
    101Required field missingRequired field missing
    102Data type errorData type error
    103Table value not foundTable value not found
    104Value too longValue too long
    198Non-Conformant CardinalityAn error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality.
    199Other HL7 ErrorAny other error with the HL7 syntax that is not captured in any of the other error codes in this set.
    200Unsupported message typeUnsupported message type
    201Unsupported event codeUnsupported event code
    202Unsupported processing idUnsupported processing id
    203Unsupported version idUnsupported version id
    204Unknown key identifierRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.
    205Duplicate key identifierRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.
    206Application record lockedRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.
    207Application errorAn application level error has occurred and the detail for that error is identified in ERR-5.

 

Expansion

This value set expansion contains 16 concepts.

CodeSystemDisplayDefinition
  0http://terminology.hl7.org/CodeSystem/v2-0357Message acceptedMessage accepted
  100http://terminology.hl7.org/CodeSystem/v2-0357Segment sequence errorSegment sequence error
  101http://terminology.hl7.org/CodeSystem/v2-0357Required field missingRequired field missing
  102http://terminology.hl7.org/CodeSystem/v2-0357Data type errorData type error
  103http://terminology.hl7.org/CodeSystem/v2-0357Table value not foundTable value not found
  104http://terminology.hl7.org/CodeSystem/v2-0357Value too longValue too long
  198http://terminology.hl7.org/CodeSystem/v2-0357Non-Conformant CardinalityAn error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality.
  199http://terminology.hl7.org/CodeSystem/v2-0357Other HL7 ErrorAny other error with the HL7 syntax that is not captured in any of the other error codes in this set.
  200http://terminology.hl7.org/CodeSystem/v2-0357Unsupported message typeUnsupported message type
  201http://terminology.hl7.org/CodeSystem/v2-0357Unsupported event codeUnsupported event code
  202http://terminology.hl7.org/CodeSystem/v2-0357Unsupported processing idUnsupported processing id
  203http://terminology.hl7.org/CodeSystem/v2-0357Unsupported version idUnsupported version id
  204http://terminology.hl7.org/CodeSystem/v2-0357Unknown key identifierRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.
  205http://terminology.hl7.org/CodeSystem/v2-0357Duplicate key identifierRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.
  206http://terminology.hl7.org/CodeSystem/v2-0357Application record lockedRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.
  207http://terminology.hl7.org/CodeSystem/v2-0357Application errorAn application level error has occurred and the detail for that error is identified in ERR-5.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code