FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5
0.0.1-snapshot-2 - informative International flag

FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions

: ResearchStudy Primary Purpose Type Code System - XML Representation

Page standards status: Informative Maturity Level: 0

Raw xml | Download


<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="research-study-prim-purp-type"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
            <p>This code system 
              <code>http://hl7.org/fhir/research-study-prim-purp-type</code> defines the following codes:
            </p>
            <table class="codes">
              <tr>
                <td style="white-space:nowrap">
                  <b>Code</b>
                </td>
                <td>
                  <b>Display</b>
                </td>
                <td>
                  <b>Definition</b>
                </td>
              </tr>
              <tr>
                <td style="white-space:nowrap">treatment
                  <a name="research-study-prim-purp-type-treatment"> </a>
                </td>
                <td>Treatment</td>
                <td>One or more interventions are being evaluated for treating a disease, syndrome, or condition.</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">prevention
                  <a name="research-study-prim-purp-type-prevention"> </a>
                </td>
                <td>Prevention</td>
                <td>One or more interventions are being assessed for preventing the development of a specific disease or health condition.</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">diagnostic
                  <a name="research-study-prim-purp-type-diagnostic"> </a>
                </td>
                <td>Diagnostic</td>
                <td>One or more interventions are being evaluated for identifying a disease or health condition.</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">supportive-care
                  <a name="research-study-prim-purp-type-supportive-care"> </a>
                </td>
                <td>Supportive Care</td>
                <td>One or more interventions are evaluated for maximizing comfort, minimizing side effects, or mitigating against a decline in the participant's health or function.</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">screening
                  <a name="research-study-prim-purp-type-screening"> </a>
                </td>
                <td>Screening</td>
                <td>One or more interventions are assessed or examined for identifying a condition, or risk factors for a condition, in people who are not yet known to have the condition or risk factor.</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">health-services-research
                  <a name="research-study-prim-purp-type-health-services-research"> </a>
                </td>
                <td>Health Services Research</td>
                <td>One or more interventions for evaluating the delivery, processes, management, organization, or financing of healthcare.</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">basic-science
                  <a name="research-study-prim-purp-type-basic-science"> </a>
                </td>
                <td>Basic Science</td>
                <td>One or more interventions for examining the basic mechanism of action (for example, physiology or biomechanics of an intervention).</td>
              </tr>
              <tr>
                <td style="white-space:nowrap">device-feasibility
                  <a name="research-study-prim-purp-type-device-feasibility"> </a>
                </td>
                <td>Device Feasibility</td>
                <td>An intervention of a device product is being evaluated to determine the feasibility of the product or to test a prototype device and not health outcomes. Such studies are conducted to confirm the design and operating specifications of a device before beginning a full clinical trial.</td>
              </tr>
            </table>
          </div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="informative"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/package-source">
    <extension url="packageId">
      <valueId value="hl7.fhir.uv.xver-r5.r4"/>
    </extension>
    <extension url="version">
      <valueString value="0.0.1-snapshot-2"/>
    </extension>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="brr"/>
  </extension>
  <url value="http://hl7.org/fhir/research-study-prim-purp-type"/>
  <version value="5.0.0"/>
  <name value="ResearchStudyPrimaryPurposeType"/>
  <title value="ResearchStudy Primary Purpose Type Code System"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2022-05-15T15:55:11.085+10:00"/>
  <publisher value="Biomedical Research and Regulation"/>
  <contact>
    <name value="Biomedical Research and Regulation"/>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/rcrim"/>
    </telecom>
  </contact>
  <description value="Codes for the main intent of a research study."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <caseSensitive value="true"/>
  <valueSet
            value="http://hl7.org/fhir/ValueSet/research-study-prim-purp-type|4.0.1"/>
  <content value="complete"/>
  <concept>
    <code value="treatment"/>
    <display value="Treatment"/>
    <definition
                value="One or more interventions are being evaluated for treating a disease, syndrome, or condition."/>
  </concept>
  <concept>
    <code value="prevention"/>
    <display value="Prevention"/>
    <definition
                value="One or more interventions are being assessed for preventing the development of a specific disease or health condition."/>
  </concept>
  <concept>
    <code value="diagnostic"/>
    <display value="Diagnostic"/>
    <definition
                value="One or more interventions are being evaluated for identifying a disease or health condition."/>
  </concept>
  <concept>
    <code value="supportive-care"/>
    <display value="Supportive Care"/>
    <definition
                value="One or more interventions are evaluated for maximizing comfort, minimizing side effects, or mitigating against a decline in the participant's health or function."/>
  </concept>
  <concept>
    <code value="screening"/>
    <display value="Screening"/>
    <definition
                value="One or more interventions are assessed or examined for identifying a condition, or risk factors for a condition, in people who are not yet known to have the condition or risk factor."/>
  </concept>
  <concept>
    <code value="health-services-research"/>
    <display value="Health Services Research"/>
    <definition
                value="One or more interventions for evaluating the delivery, processes, management, organization, or financing of healthcare."/>
  </concept>
  <concept>
    <code value="basic-science"/>
    <display value="Basic Science"/>
    <definition
                value="One or more interventions for examining the basic mechanism of action (for example, physiology or biomechanics of an intervention)."/>
  </concept>
  <concept>
    <code value="device-feasibility"/>
    <display value="Device Feasibility"/>
    <definition
                value="An intervention of a device product is being evaluated to determine the feasibility of the product or to test a prototype device and not health outcomes. Such studies are conducted to confirm the design and operating specifications of a device before beginning a full clinical trial."/>
  </concept>
</CodeSystem>