This page is part of the Point-of-care Device FHIR IG (v0.1.0: STU 1 Draft) based on FHIR R3. . For a full list of available versions, see the Directory of published versions

Instance Extension

Canonical URL

http://devices.fhir.org/StructureDefinition/devicecomponent-instance

Extension Definition

NameFlagsCard.Type
extension0..*Extension
url1..1uriFixed Value
valueUnsignedInt0..1unsignedInt

Example (XML view)

Example of a Blood Pressure VMD DeviceComponent

<DeviceComponent>
    <id value="433" />
    <meta>
        <profile value="http://devices.fhir.org/StructureDefinition/VmdDeviceComponent" />
    </meta>
    <extension url="http://devices.fhir.org/StructureDefinition/devicecomponent-instance">
        <valueUnsignedInt value="1" />
    </extension>
    <identifier>
        <use value="temp" />
        <system value="urn:ietf:rfc:3986" />
        <value value="urn:uuid:aa0e1091-5dfe-435b-bb96-c5ce2992e2dc" />
    </identifier>
    <type>
        <coding>
            <system value="urn:iso:std:iso:11073:10101" />
            <code value="69710" />
            <display value="MDC_DEV_ANALY_PRESS_BLD_VMD" />
        </coding>
    </type>
    <source>
        <reference value="Device/72" />
    </source>
    <parent>
        <reference value="DeviceComponent/427" />
    </parent>
    <operationalStatus>
        <coding>
            <system value="http://hl7.org/fhir/operational-status" />
            <code value="transduc-discon" />
            <display value="Transducer Disconnected" />
        </coding>
    </operationalStatus>
</DeviceComponent>

Example (JSON view)

Example of a Blood Pressure VMD DeviceComponent

{
    "resourceType":"DeviceComponent",
    "id":"433",
    "meta":{
        "profile": [
            "http://devices.fhir.org/StructureDefinition/VmdDeviceComponent"
        ]
    },
    "extension": [
        {
            "url":"http://devices.fhir.org/StructureDefinition/devicecomponent-instance",
            "valueUnsignedInt":"1"
        }
    ],
    "identifier":{
        "use":"temp",
        "system":"urn:ietf:rfc:3986",
        "value":"urn:uuid:aa0e1091-5dfe-435b-bb96-c5ce2992e2dc"
    },
    "type":{
        "coding": [
            {
                "system":"urn:iso:std:iso:11073:10101",
                "code":"69710",
                "display":"MDC_DEV_ANALY_PRESS_BLD_VMD"
            }
        ]
    },
    "source":{
        "reference":"Device/72"
    },
    "parent":{
        "reference":"DeviceComponent/427"
    },
    "operationalStatus": [
        {
            "coding": [
                {
                    "system":"http://hl7.org/fhir/operational-status",
                    "code":"transduc-discon",
                    "display":"Transducer Disconnected"
                }
            ]
        }
    ]
}