Left: | US Core Body Weight Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight) |
Right: | Decedent Usual Work (http://hl7.org/fhir/us/vrdr/StructureDefinition/vrdr-decedent-usual-work) |
Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight' vs 'http://hl7.org/fhir/us/vrdr/StructureDefinition/vrdr-decedent-usual-work' |
Error | StructureDefinition.version | Values for version differ: '6.1.0' vs '2.2.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreBodyWeightProfile' vs 'DecedentUsualWork' |
Information | StructureDefinition.title | Values for title differ: 'US Core Body Weight Profile' vs 'Decedent Usual Work' |
Information | StructureDefinition.date | Values for date differ: '2022-04-20' vs '2023-10-17T18:39:37+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International / Public Health' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/us/odh/StructureDefinition/odh-UsualWork' |
Information | StructureDefinition.short | Values for short differ: 'US Core Body Weight Profile' vs 'Usual Work' |
Information | StructureDefinition.definition | Values for definition differ: '\-' vs 'Related data elements about the work a person reports having performed for the longest amount of time during his or her life, regardless of the person’s current job and regardless of whether or not the person performed this work for a continuous time. Knowledge of person’s Usual Work can potentially assist in diagnosis, treatment and/or prevention of chronic condition(s) or conditions with a long latency. The potential for exposure to Occupational Hazard(s) related to an Occupation and/or an Industry can change over time, and a person could have been in and out of their Usual Work over time, so additional data are helpful to fully evaluate the possible impact of the person’s Usual Work on their health and guide appropriate use of screening tests to detect early disease. Example: a person has worked for a total of 30 years as a building carpenter (Occupation), but in various industries, mostly hotel construction. Her Usual Occupation is ‘building carpenter’ and her Usual Industry is ‘hotel construction.’ Usual Work does not include work that was unpaid or voluntary.' |
Information | StructureDefinition.comment | Values for comment differ: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' |
Information | StructureDefinition.short | Values for short differ: 'Fulfills plan, proposal or order' vs 'The plan, proposal or order that is fulfilled in whole or in part by this observation' |
Information | StructureDefinition.definition | Values for definition differ: 'A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.' vs 'The plan, proposal or order that is fulfilled in whole or in part by this observation.' |
Error | Observation.basedOn | Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan], CanonicalType[http://hl7.org/fhir/StructureDefinition/DeviceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/NutritionOrder], CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) |
Information | StructureDefinition.short | Values for short differ: 'Part of referenced event' vs 'The larger procedure that this particular observation is a component or step' |
Information | StructureDefinition.definition | Values for definition differ: 'A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.' vs 'The larger procedure that this particular observation is a component or step.' |
Information | StructureDefinition.comment | Values for comment differ: 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below for guidance on referencing another Observation.' vs 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below for guidance on referencing another Observation.' |
Error | Observation.partOf | Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationAdministration], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationDispense], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationStatement], CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure], CanonicalType[http://hl7.org/fhir/StructureDefinition/Immunization], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure]]) |
Information | StructureDefinition.short | Values for short differ: '(USCDI) registered | preliminary | final | amended +' vs 'registered | preliminary | final | amended +' |
Warning | Observation.status | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Classification of type of observation' vs 'Classification of type of observation' |
Warning | Observation.category | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | Observation.category | Element minimum cardinalities differ: '1' vs '0' |
Information | Observation.category | Element maximum cardinalities differ: '2147483647' vs '1' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Body Weight' vs 'Type of observation (code / type)' |
Information | StructureDefinition.definition | Values for definition differ: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.' |
Information | StructureDefinition.requirements | Values for requirements differ: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.' |
Warning | Observation.code | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Who and/or what the observation is about' vs 'The subject of an observation' |
Information | StructureDefinition.definition | Values for definition differ: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'The subject of an observation.' |
Warning | Observation.subject | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.comment | Values for comment differ: 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/extension-observation-focuscode.html).' vs 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/R4/extension-observation-focuscode.html).' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation' |
Information | StructureDefinition.definition | Values for definition differ: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Information | StructureDefinition.comment | Values for comment differ: 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/R4/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' |
Warning | Observation.effective[x] | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | Observation.effective[x] | Element minimum cardinalities differ: '1' vs '0' |
Information | StructureDefinition.comment | Values for comment differ: 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' vs 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/R4/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Vital Signs Value' vs 'Actual result' |
Information | StructureDefinition.definition | Values for definition differ: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.' |
Information | StructureDefinition.comment | Values for comment differ: 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' vs 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Warning | Observation.value[x] | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Why the result is missing' vs 'The reason that there is no value available for the Occupation.' |
Information | StructureDefinition.definition | Values for definition differ: 'Provides a reason why the expected value in the element Observation.value[x] is missing.' vs 'The reason that there is no value available for the Occupation.' |
Warning | Observation.dataAbsentReason | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | Observation.interpretation | Element maximum cardinalities differ: '2147483647' vs '0' |
Information | StructureDefinition.comment | Values for comment differ: 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/extension-bodysite.html).' vs 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/R4/extension-bodysite.html).' |
Information | Observation.bodySite | Element maximum cardinalities differ: '1' vs '0' |
Information | Observation.method | Element maximum cardinalities differ: '1' vs '0' |
Information | Observation.specimen | Element maximum cardinalities differ: '1' vs '0' |
Information | Observation.device | Element maximum cardinalities differ: '1' vs '0' |
Information | Observation.referenceRange | Element maximum cardinalities differ: '2147483647' vs '0' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' |
Information | StructureDefinition.short | Values for short differ: 'Used when reporting vital signs panel components' vs 'Related resource that belongs to the Observation group' |
Information | StructureDefinition.definition | Values for definition differ: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' |
Information | StructureDefinition.comment | Values for comment differ: 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/questionnaireresponse.html) into a final score and represent the score as an Observation.' vs 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/R4/questionnaireresponse.html) into a final score and represent the score as an Observation.' |
Information | Observation.hasMember | Element maximum cardinalities differ: '2147483647' vs '0' |
Error | Observation.hasMember | Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Information | StructureDefinition.comment | Values for comment differ: 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below.' vs 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below.' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Component observations' vs 'Component results' |
Information | StructureDefinition.definition | Values for definition differ: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' |
Information | StructureDefinition.comment | Values for comment differ: 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/observation.html#notes) below.' vs 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/R4/observation.html#notes) below.' |
Warning | Observation.component | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | Observation.component | Element minimum cardinalities differ: '0' vs '1' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Type of component observation (code / type)' vs 'Type of component observation (code / type)' |
Warning | Observation.component.code | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Vital Sign Component Value' vs 'Actual component result' |
Information | StructureDefinition.definition | Values for definition differ: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.' |
Information | StructureDefinition.comment | Values for comment differ: 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' vs 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Warning | Observation.component.value[x] | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: '(USCDI) Why the component result is missing' vs 'Why the component result is missing' |
Warning | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport: 'true' vs 'false' |
Name | Value | Comments | |
---|---|---|---|
abstract | false | ||
baseDefinition | http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs | http://hl7.org/fhir/us/odh/StructureDefinition/odh-UsualWork |
|
copyright | Used by permission of HL7 International, all rights reserved Creative Commons License |
| |
date | 2022-04-20 | 2023-10-17T18:39:37+00:00 |
|
description | To promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch body weight observations with a standard LOINC code and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies which *additional* core elements, extensions, vocabularies, and value sets **SHALL** be present and constrains the way the elements are used when using the profile. It provides the floor for standards development for specific use cases. | Decedent Usual Work (UsualWork) |
|
experimental | false |
| |
fhirVersion | 4.0.1 | ||
jurisdiction | |||
jurisdiction[0] | urn:iso:std:iso:3166#US | ||
kind | resource | ||
name | USCoreBodyWeightProfile | DecedentUsualWork |
|
publisher | HL7 International - Cross-Group Projects | HL7 International / Public Health |
|
purpose | |||
status | active | ||
title | US Core Body Weight Profile | Decedent Usual Work |
|
type | Observation | ||
url | http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight | http://hl7.org/fhir/us/vrdr/StructureDefinition/vrdr-decedent-usual-work |
|
version | 6.1.0 | 2.2.0 |
|
Name | L Flags | L Card. | L Type | L Description & Constraints | R Flags | R Card. | L Type | L Description & Constraints | Comments | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreVitalSignsProfile | US Core Body Weight Profile | C | 0..* | UsualWork | Usual Work | |||||||||
id | Σ | 0..1 | id | Logical id of this artifact | Σ | 0..1 | id | Logical id of this artifact | |||||||||
meta | Σ | 0..1 | Meta | Metadata about the resource | Σ | 0..1 | Meta | Metadata about the resource | |||||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ?!Σ | 0..1 | uri | A set of rules under which this content was created | |||||||||
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
| 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
| |||||||||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||||||||
contained | 0..* | Resource | Contained, inline Resources | 0..* | Resource | Contained, inline Resources | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ?! | 0..* | Extension | Extensions that cannot be ignored | |||||||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | Σ | 0..* | Identifier | Business Identifier for observation | |||||||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | Σ | 0..* | Reference(ServiceRequest) | The plan, proposal or order that is fulfilled in whole or in part by this observation |
| ||||||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | Σ | 0..* | Reference(Procedure) | The larger procedure that this particular observation is a component or step |
| ||||||||
status | ?!SΣ | 1..1 | code | (USCDI) registered | preliminary | final | amended + Binding: ?? (required) | ?!Σ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required): Codes providing the status of an observation. |
| ||||||||
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ?? (preferred): Codes for high level observation categories. | 0..1 | CodeableConcept | Classification of type of observation Binding: ?? (preferred): Codes for high level observation categories. |
| |||||||||
id | 0..1 | string | Unique id for inter-element referencing |
| |||||||||||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url |
| |||||||||||||
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code |
| ||||||||||||
text | Σ | 0..1 | string | Plain text representation of the concept |
| ||||||||||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Body Weight Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: {"coding":[{"system":"http://loinc.org","code":"29463-7"}]} | Σ | 1..1 | CodeableConcept | Type of observation (code / type) Binding: ?? (example): Codes identifying names of simple observations. |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing |
| |||||||||||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url |
| |||||||||||||
Slices for coding | Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code |
| ||||||||||||
text | Σ | 0..1 | string | Plain text representation of the concept |
| ||||||||||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | (USCDI) Who and/or what the observation is about | Σ | 1..1 | Reference(Decedent) | The subject of an observation |
| ||||||||
focus | ΣTU | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | Σ | 0..* | Reference(RelatedPerson) | What the observation is about, when it is not about the subject of record | |||||||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | |||||||||
effective[x] | SΣC | 1..1 | dateTime S, Period | (USCDI) Often just a dateTime for Vital Signs | Σ | 0..1 | Period | Clinically relevant time/time-period for observation Slice: Unordered, Closed by type:$this |
| ||||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | Σ | 0..1 | instant | Date/Time this version was made available | |||||||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | Σ | 0..* | Reference(Practitioner | Organization | US Core Patient Profile | RelatedPerson) | Who is responsible for the observation | |||||||||
Slices for value[x] | SΣC | 0..1 | Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | (USCDI) Vital Signs Value Slice: Unordered, Open by type:$this Binding: ?? (extensible): Common UCUM units for recording Vital Signs. | ΣC | 0..1 | CodeableConcept | Actual result Slice: Unordered, Closed by type:$this |
| ||||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | C | 0..1 | CodeableConcept | The reason that there is no value available for the Occupation. Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
| ||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | 0..0 |
| ||||||||||||
note | 0..* | Annotation | Comments about the observation | 0..* | Annotation | Comments about the observation | |||||||||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: ?? (example): Codes describing anatomical locations. May include laterality. | 0..0 |
| ||||||||||||
method | 0..1 | CodeableConcept | How it was done Binding: ?? (example): Methods for simple observations. | 0..0 |
| ||||||||||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | 0..0 |
| ||||||||||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | 0..0 |
| ||||||||||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | C | 0..0 |
| ||||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
low | C | 0..1 | ?? | Low Range, if relevant | C | 0..1 | ?? | Low Range, if relevant | |||||||||
high | C | 0..1 | ?? | High Range, if relevant | C | 0..1 | ?? | High Range, if relevant | |||||||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (extensible): Code for the meaning of a reference range. | |||||||||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. | 0..* | CodeableConcept | Reference range population Binding: ?? (extensible): Codes identifying the population the reference range applies to. | |||||||||||
age | 0..1 | Range | Applicable age range, if relevant | 0..1 | Range | Applicable age range, if relevant | |||||||||||
text | 0..1 | string | Text based reference range in an observation | 0..1 | string | Text based reference range in an observation | |||||||||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | Σ | 0..0 |
| ||||||||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | Σ | 0..* | Reference(DocumentReference | Media | QuestionnaireResponse | Observation) | Related measurements the observation is made from | |||||||||
component | SΣC | 0..* | BackboneElement | (USCDI) Component observations | Σ | 1..* | BackboneElement | Component results Slice: Unordered, Open by value:code |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: ?? (example): Codes identifying names of simple observations. |
| ||||||||
value[x] | SΣC | 0..1 | Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | (USCDI) Vital Sign Component Value Binding: ?? (extensible): Common UCUM units for recording Vital Signs. | Σ | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result |
| ||||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | C | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
| ||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | |||||||||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||||||||
Documentation for this format |