Intersection of http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs and http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-usual-work-vr

This is the set of resources that conform to both US Core Vital Signs Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs) and Observation - Usual Work (http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-usual-work-vr).

Structure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C0..*left: US Core Vital Signs Profile; right: Usual Work
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... meta Σ0..1MetaMetadata about the resource
ele-1: All FHIR elements must have a @value or children
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... language 0..1codeLanguage of the resource content
Binding: ?? (preferred): A human language.

Additional BindingsPurpose
??Max Binding

ele-1: All FHIR elements must have a @value or children
... contained 0..*ResourceContained, inline Resources
... extension 0..*Extensionleft: Additional content defined by implementations; right: Extension
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... identifier Σ0..*IdentifierBusiness Identifier for observation
ele-1: All FHIR elements must have a @value or children
... basedOn Σ0..*left: Fulfills plan, proposal or order; right: The plan, proposal or order that is fulfilled in whole or in part by this observation
ele-1: All FHIR elements must have a @value or children
... partOf Σ0..*left: Part of referenced event; right: The larger procedure that this particular observation is a component or step
ele-1: All FHIR elements must have a @value or children
... status ?!SΣ1..1codeleft: (USCDI) registered | preliminary | final | amended +; right: registered | preliminary | final | amended +
Binding: ?? (required): Codes providing the status of an observation.


ele-1: All FHIR elements must have a @value or children
... category S1..1CodeableConceptleft: (USCDI) Classification of type of observation; right: Classification of type of observation
Binding: ?? (preferred): Codes for high level observation categories.


ele-1: All FHIR elements must have a @value or children
... code SΣ1..1CodeableConceptleft: (USCDI) Coded Responses from C-CDA Vital Sign Results; right: Type of observation (code / type)
Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


ele-1: All FHIR elements must have a @value or children
... subject SΣ1..1Reference(Patient - Vital Records)left: (USCDI) Who and/or what the observation is about; right: The subject of an observation
ele-1: All FHIR elements must have a @value or children
... focus Σ0..*Reference(Related Person - Parent Vital Records)What the observation is about, when it is not about the subject of record
ele-1: All FHIR elements must have a @value or children
... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is made
ele-1: All FHIR elements must have a @value or children
... effective[x] SΣC1..1left: (USCDI) Often just a dateTime for Vital Signs; right: Clinically relevant time/time-period for observation
ele-1: All FHIR elements must have a @value or children
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
.... effectiveDateTimedateTime S
.... effectivePeriodPeriod
... issued Σ0..1instantDate/Time this version was made available
ele-1: All FHIR elements must have a @value or children
... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
ele-1: All FHIR elements must have a @value or children
... value[x] SΣ0..1left: (USCDI) Vital Signs Value; right: Actual result
Binding: ?? (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
.... valueQuantityQuantity S
.... valueCodeableConceptCodeableConcept
.... valueStringstring
.... valueBooleanboolean
.... valueIntegerinteger
.... valueRangeRange
.... valueRatioRatio
.... valueSampledDataSampledData
.... valueTimetime
.... valueDateTimedateTime
.... valuePeriodPeriod
... dataAbsentReason S0..1CodeableConceptleft: (USCDI) Why the result is missing; right: The reason that there is no value available for the Occupation.
Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
... note 0..*AnnotationComments about the observation
ele-1: All FHIR elements must have a @value or children
... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
ele-1: All FHIR elements must have a @value or children
... component SΣC1..*BackboneElementleft: (USCDI) Component observations; right: Component results
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... code SΣ1..1CodeableConceptleft: (USCDI) Type of component observation (code / type); right: Type of component observation (code / type)
Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


ele-1: All FHIR elements must have a @value or children
.... value[x] SΣ0..1left: (USCDI) Vital Sign Component Value; right: Actual component result
Binding: ?? (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
..... valueQuantityQuantity S
..... valueCodeableConceptCodeableConcept
..... valueStringstring
..... valueBooleanboolean
..... valueIntegerinteger
..... valueRangeRange
..... valueRatioRatio
..... valueSampledDataSampledData
..... valueTimetime
..... valueDateTimedateTime
..... valuePeriodPeriod
.... dataAbsentReason S0..1CodeableConceptleft: (USCDI) Why the component result is missing; right: Why the component result is missing
Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
.... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ?? (extensible): Codes identifying interpretations of observations.


ele-1: All FHIR elements must have a @value or children
.... referenceRange 0..*Provides guide for interpretation of component result
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format