Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus vs http://hl7.org/fhir/us/vitals/StructureDefinition/HeadOccipitalFrontalCircumference

Left:US Core Smoking Status Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus)
Right:Head Occipital-Frontal Circumference (http://hl7.org/fhir/us/vitals/StructureDefinition/HeadOccipitalFrontalCircumference)

Messages

StructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus' vs 'http://hl7.org/fhir/us/vitals/StructureDefinition/HeadOccipitalFrontalCircumference'Information
StructureDefinition.versionValues for version differ: '3.1.0' vs '0.1.0'Information
StructureDefinition.nameValues for name differ: 'USCoreSmokingStatusProfile' vs 'HeadOccipitalFrontalCircumference'Information
StructureDefinition.titleValues for title differ: 'US Core Smoking Status Observation Profile' vs 'Head Occipital-Frontal Circumference'Information
StructureDefinition.statusValues for status differ: 'active' vs 'draft'Information
StructureDefinition.dateValues for date differ: '2019-05-21T00:00:00+10:00' vs '2019-05-29'Information
StructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'HSPC'Information
StructureDefinition.kindValues for kind differ: 'resource' vs 'complex-type'Warning
StructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/Observation' vs 'http://hl7.org/fhir/StructureDefinition/vitalsigns'Error
ObservationElements differ in short: "Measurements and simple assertions" "Head Circumference"Warning
ObservationElements differ in definition: "The US Core Smoking Status Observation Profile is based upon the core FHIR Observation Resource and created to meet the 2015 Edition Common Clinical Data Set 'Smoking status' requirements." "Head Occipital/Frontal Circumference by Tape Measure, the measured length around and individual's head via a tape measure."Warning
Observation.categoryElements differ in definition for mustSupport: "false" "true"Error
Observation.codeElements differ in short: "Smoking Status" "Coded Responses from C-CDA Vital Sign Results"Warning
Observation.codeElements differ in definition: "Describes what was observed. Sometimes this is called the observation "name"." "Coded Responses from C-CDA Vital Sign Results."Warning
Observation.codeElements differ in requirements: "Knowing what kind of observation is being made is essential to understanding the observation." "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)."Warning
Observation.effective[x]Elements differ in short: "Clinically relevant time/time-period for observation" "Often just a dateTime for Vital Signs"Warning
Observation.effective[x]Elements differ in definition: "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself." "Often just a dateTime for Vital Signs."Warning
Observation.effective[x]Elements differ in definition for mustSupport: "false" "true"Error
Observation.issuedElements differ in definition for mustSupport: "true" "false"Error
Observation.value[x]Elements differ in short: "Actual result" "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept."Warning
Observation.value[x]Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept."Warning
Observation.value[x]Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."Warning
Observation.value[x]Elements differ in definition for mustSupport: "false" "true"Error
Observation.dataAbsentReasonElements differ in definition for mustSupport: "false" "true"Error
Observation.hasMemberElements differ in short: "Related resource that belongs to the Observation group" "Used when reporting vital signs panel components"Warning
Observation.hasMemberElements differ in definition: "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group." "Used when reporting vital signs panel components."Warning
Observation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])Error
Observation.componentElements differ in short: "Component results" "Used when reporting systolic and diastolic blood pressure."Warning
Observation.componentElements differ in definition: "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations." "Used when reporting systolic and diastolic blood pressure."Warning
Observation.componentElements differ in definition for mustSupport: "false" "true"Error
Observation.component.codeElements differ in definition for mustSupport: "false" "true"Error
Observation.component.codeElements differ in binding.description: "Codes identifying names of simple observations." "This identifies the vital sign result type."Warning
Observation.component.value[x]Elements differ in short: "Actual component result" "Vital Sign Value recorded with UCUM"Warning
Observation.component.value[x]Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Sign Value recorded with UCUM."Warning
Observation.component.value[x]Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."Warning
Observation.component.value[x]Elements differ in definition for mustSupport: "false" "true"Error
Observation.component.dataAbsentReasonElements differ in definition for mustSupport: "false" "true"Error

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observationhttp://hl7.org/fhir/StructureDefinition/vitalsigns
    • Values Differ
    .copyright
      .date2019-05-21T00:00:00+10:002019-05-29
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve patient's Smoking Status information.Head Occipital/Frontal Circumference by Tape Measure, the measured length around and individual's head via a tape measure.
      • Values Differ
      .experimentalfalse
      • Removed this item
      .fhirVersion4.0.1
        .kindresourcecomplex-type
        • Values Differ
        .nameUSCoreSmokingStatusProfileHeadOccipitalFrontalCircumference
        • Values Differ
        .publisherHL7 US Realm Steering CommitteeHSPC
        • Values Differ
        .purpose
          .statusactivedraft
          • Values Differ
          .titleUS Core Smoking Status Observation ProfileHead Occipital-Frontal Circumference
          • Values Differ
          .typeObservation
            .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatushttp://hl7.org/fhir/us/vitals/StructureDefinition/HeadOccipitalFrontalCircumference
            • Values Differ
            .version3.1.00.1.0
            • Values Differ

            Structure

            NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
            .. Observation II
            • Elements differ in short: "Measurements and simple assertions" "Head Circumference"
            • Elements differ in definition: "The US Core Smoking Status Observation Profile is based upon the core FHIR Observation Resource and created to meet the 2015 Edition Common Clinical Data Set 'Smoking status' requirements." "Head Occipital/Frontal Circumference by Tape Measure, the measured length around and individual's head via a tape measure."
            ... id ΣΣ
              ... meta ΣIΣI
                ... implicitRules ?!ΣI?!ΣI
                  ... language II
                    ... text II
                      ... contained
                        ... extension IExtensionIExtension
                          ... modifierExtension ?!I?!I
                            ... identifier ΣIΣI
                              ... basedOn ΣIΣI
                                ... partOf ΣIΣI
                                  ... status ?!SΣI?!SΣI
                                    ... category ISI(Slice Definition)
                                    • Elements differ in definition for mustSupport: "false" "true"
                                    ... code SΣISΣI
                                    • Elements differ in short: "Smoking Status" "Coded Responses from C-CDA Vital Sign Results"
                                    • Elements differ in definition: "Describes what was observed. Sometimes this is called the observation "name"." "Coded Responses from C-CDA Vital Sign Results."
                                    • Elements differ in requirements: "Knowing what kind of observation is being made is essential to understanding the observation." "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)."
                                    ... subject SΣISΣI
                                      ... focus ΣIΣI
                                        ... encounter ΣIΣI
                                          ... effective[x] ΣISΣI
                                          • Elements differ in short: "Clinically relevant time/time-period for observation" "Often just a dateTime for Vital Signs"
                                          • Elements differ in definition: "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself." "Often just a dateTime for Vital Signs."
                                          • Elements differ in definition for mustSupport: "false" "true"
                                          ... issued SΣIΣI
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... performer ΣIΣI
                                            ... value[x] ΣI(Slice Definition)SΣI(Slice Definition)
                                            • Elements differ in short: "Actual result" "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept."
                                            • Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept."
                                            • Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."
                                            • Elements differ in definition for mustSupport: "false" "true"
                                            ... dataAbsentReason ISI
                                            • Elements differ in definition for mustSupport: "false" "true"
                                            ... interpretation II
                                              ... note II
                                                ... bodySite II
                                                  ... method II
                                                    ... specimen II
                                                      ... device II
                                                        ... referenceRange II
                                                          .... id
                                                            .... extension IExtensionIExtension
                                                              .... modifierExtension ?!ΣI?!ΣI
                                                                .... low II
                                                                  .... high II
                                                                    .... type II
                                                                      .... appliesTo II
                                                                        .... age II
                                                                          .... text II
                                                                            ... hasMember ΣIΣI
                                                                            • Elements differ in short: "Related resource that belongs to the Observation group" "Used when reporting vital signs panel components"
                                                                            • Elements differ in definition: "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group." "Used when reporting vital signs panel components."
                                                                            • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
                                                                            ... derivedFrom ΣIΣI
                                                                              ... component ΣISΣI
                                                                              • Elements differ in short: "Component results" "Used when reporting systolic and diastolic blood pressure."
                                                                              • Elements differ in definition: "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations." "Used when reporting systolic and diastolic blood pressure."
                                                                              • Elements differ in definition for mustSupport: "false" "true"
                                                                              .... id
                                                                                .... extension IExtensionIExtension
                                                                                  .... modifierExtension ?!ΣI?!ΣI
                                                                                    .... code ΣISΣI
                                                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                                                    • Elements differ in binding.description: "Codes identifying names of simple observations." "This identifies the vital sign result type."
                                                                                    .... value[x] ΣISΣI
                                                                                    • Elements differ in short: "Actual component result" "Vital Sign Value recorded with UCUM"
                                                                                    • Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Sign Value recorded with UCUM."
                                                                                    • Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."
                                                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                                                    .... dataAbsentReason ISI
                                                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                                                    .... interpretation II
                                                                                      .... referenceRange II

                                                                                        doco Documentation for this format