Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/vitals/StructureDefinition/AverageBloodPressure

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:Average Blood Pressure (http://hl7.org/fhir/us/vitals/StructureDefinition/AverageBloodPressure)

Messages

StructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/vitals/StructureDefinition/AverageBloodPressure'Information
StructureDefinition.versionValues for version differ: '3.1.0' vs '0.1.0'Information
StructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'AverageBloodPressure'Information
StructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'Average Blood Pressure'Information
StructureDefinition.statusValues for status differ: 'active' vs 'draft'Information
StructureDefinition.dateValues for date differ: '2019-08-20T00:00:00+10:00' vs '2019-05-29'Information
StructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'Logica Health'Information
StructureDefinition.kindValues for kind differ: 'resource' vs 'complex-type'Warning
StructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/oxygensat' vs 'http://hl7.org/fhir/StructureDefinition/vitalsigns'Error
ObservationElements differ in short: "FHIR Oxygen Saturation Profile" "BloodPressurePanel"Warning
ObservationElements differ in definition: "This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure." "Blood Pressure Panel; a grouping of systolic, diastolic, and mean arterial blood pressure components."Warning
Observation.extensionElements differ in short: "Additional content defined by implementations" "Extension"Warning
Observation.extensionElements differ in definition: "May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension." "An Extension"Warning
Observation.codeElements differ in short: "Oxygen Saturation by Pulse Oximetry" "Coded Responses from C-CDA Vital Sign Results"Warning
Observation.codeElements differ in definition: "Oxygen Saturation." "Coded Responses from C-CDA Vital Sign Results."Warning
Observation.codeElements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."Warning
Observation.code.codingElements differ in definition for mustSupport: "true" "false"Error
Observation.bodySiteExample/preferred bindings differ at Observation.bodySite using binding from AverageBloodPressureInformation
Observation.bodySiteElements differ in binding.description: "Codes describing anatomical locations. May include laterality." "A set of codes that describe where on/in the body an observation or procedure took place"Warning
Observation.methodExample/preferred bindings differ at Observation.method using binding from AverageBloodPressureInformation
Observation.methodElements differ in binding.description: "Methods for simple observations." "A set of codes that describe the method used to measure a blood pressure"Warning
Observation.deviceElements differ in short: "(Measurement) Device" "Blood Pressure Device"Warning
Observation.deviceElements differ in definition for mustSupport: "false" "true"Error
Observation.componentElements differ in short: "Used when reporting systolic and diastolic blood pressure." "Blood pressure components"Warning

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/oxygensathttp://hl7.org/fhir/StructureDefinition/vitalsigns
    • Values Differ
    .copyright
      .date2019-08-20T00:00:00+10:002019-05-29
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for use in querying and retrieving inspired O2 by pulse oximetry observations.Blood Pressure Panel; a grouping of systolic, diastolic, and mean arterial blood pressure components.
      • Values Differ
      .experimentalfalse
      • Removed this item
      .fhirVersion4.0.1
        .kindresourcecomplex-type
        • Values Differ
        .nameUSCorePulseOximetryProfileAverageBloodPressure
        • Values Differ
        .publisherHL7 US Realm Steering CommitteeLogica Health
        • Values Differ
        .purpose
          .statusactivedraft
          • Values Differ
          .titleUS Core Pulse Oximetry ProfileAverage Blood Pressure
          • Values Differ
          .typeObservation
            .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/vitals/StructureDefinition/AverageBloodPressure
            • Values Differ
            .version3.1.00.1.0
            • Values Differ

            Structure

            NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
            .. Observation II
            • Elements differ in short: "FHIR Oxygen Saturation Profile" "BloodPressurePanel"
            • Elements differ in definition: "This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure." "Blood Pressure Panel; a grouping of systolic, diastolic, and mean arterial blood pressure components."
            ... id ΣΣ
              ... meta ΣIΣI
                ... implicitRules ?!ΣI?!ΣI
                  ... language II
                    ... text II
                      ... contained
                        ... extension IExtensionIExtension
                        • Elements differ in short: "Additional content defined by implementations" "Extension"
                        • Elements differ in definition: "May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension." "An Extension"
                        ... modifierExtension ?!I?!I
                          ... identifier ΣIΣI
                            ... basedOn ΣIΣI
                              ... partOf ΣIΣI
                                ... status ?!SΣI?!SΣI
                                  ... category SI(Slice Definition)SI(Slice Definition)
                                    ... code SΣISΣI
                                    • Elements differ in short: "Oxygen Saturation by Pulse Oximetry" "Coded Responses from C-CDA Vital Sign Results"
                                    • Elements differ in definition: "Oxygen Saturation." "Coded Responses from C-CDA Vital Sign Results."
                                    • Elements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                    .... id
                                      .... extension IExtensionIExtension
                                        .... coding SΣI(Slice Definition)ΣI
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        .... text ΣIΣI
                                          ... subject SΣISΣI
                                            ... focus ΣIΣI
                                              ... encounter ΣIΣI
                                                ... effective[x] SΣISΣI
                                                  ... issued ΣIΣI
                                                    ... performer ΣIΣI
                                                      ... value[x] SΣI(Slice Definition)SΣI
                                                        ... dataAbsentReason SISI
                                                          ... interpretation II
                                                            ... note II
                                                              ... bodySite II
                                                              • Example/preferred bindings differ at Observation.bodySite using binding from AverageBloodPressure
                                                              • Elements differ in binding.description: "Codes describing anatomical locations. May include laterality." "A set of codes that describe where on/in the body an observation or procedure took place"
                                                              ... method II
                                                              • Example/preferred bindings differ at Observation.method using binding from AverageBloodPressure
                                                              • Elements differ in binding.description: "Methods for simple observations." "A set of codes that describe the method used to measure a blood pressure"
                                                              ... specimen II
                                                                ... device ISI
                                                                • Elements differ in short: "(Measurement) Device" "Blood Pressure Device"
                                                                • Elements differ in definition for mustSupport: "false" "true"
                                                                ... referenceRange II
                                                                  .... id
                                                                    .... extension IExtensionIExtension
                                                                      .... modifierExtension ?!ΣI?!ΣI
                                                                        .... low II
                                                                          .... high II
                                                                            .... type II
                                                                              .... appliesTo II
                                                                                .... age II
                                                                                  .... text II
                                                                                    ... hasMember ΣIΣI
                                                                                      ... derivedFrom ΣIΣI
                                                                                        ... component SΣI(Slice Definition)SΣI(Slice Definition)
                                                                                        • Elements differ in short: "Used when reporting systolic and diastolic blood pressure." "Blood pressure components"
                                                                                        .... id
                                                                                          .... extension IExtensionIExtension
                                                                                            .... modifierExtension ?!ΣI?!ΣI
                                                                                              .... code SΣISΣI
                                                                                                .... value[x] SΣISΣI
                                                                                                  .... dataAbsentReason SISI
                                                                                                    .... interpretation II
                                                                                                      .... referenceRange II

                                                                                                        doco Documentation for this format