Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate vs http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationRace

Left:US Core Heart Rate Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate)
Right:SDOHCC Observation Race (http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationRace)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate' vs 'http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationRace'
ErrorStructureDefinition.versionValues for version differ: '4.1.0' vs '1.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreHeartRateProfile' vs 'SDOHCCObservationRace'
InformationStructureDefinition.titleValues for title differ: 'US Core Heart Rate Profile' vs 'SDOHCC Observation Race'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2020-11-17' vs '2021-12-07T14:30:02+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International - Patient Care WG'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Heart Rate Profile' 'Race observation'
WarningObservationElements differ in definition: 'Defines constraints on Observation to represent heart rate observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.' 'For observations about the race of an individual.'
WarningObservation.extensionElements differ in short: 'Additional content defined by implementations' 'Extension'
WarningObservation.extensionElements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' 'An Extension'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Heart Rate' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' 'Codes identifying names of simple observations.'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.performerElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.dataAbsentReasonElements differ in comments: 'Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be 'detected', 'not detected', 'inconclusive', or 'specimen unsatisfactory'. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code 'error' could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.' 'Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values.'
ErrorObservation.methodElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
ErrorObservation.derivedFromElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.componentElements differ in short: 'Component observations' 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes.'
WarningObservation.componentElements differ in requirements: 'Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.' 'Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable).'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2020-11-172021-12-07T14:30:02+00:00
    • Values Differ
    .descriptionDefines constraints on Observation to represent heart rate observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.Profile for observations about race using Office of Management and Budget (OMB) race category codes and CDC race codes. This profile is intended for draft use only. The Cross-Group Projects work group granted an exception to US Core on 11/18/2021 - Jira ticket 34245.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCoreHeartRateProfileSDOHCCObservationRace
            • Values Differ
            .publisherHL7 International - Cross-Group ProjectsHL7 International - Patient Care WG
            • Values Differ
            .purpose
              .statusactivedraft
              • Values Differ
              .titleUS Core Heart Rate ProfileSDOHCC Observation Race
              • Values Differ
              .typeObservation
                .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-ratehttp://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationRace
                • Values Differ
                .version4.1.01.1.0
                • Values Differ

                Structure

                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                .. Observation II
                • Elements differ in short: "US Core Heart Rate Profile" "Race observation"
                • Elements differ in definition: "Defines constraints on Observation to represent heart rate observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile." "For observations about the race of an individual."
                ... id ΣΣ
                  ... meta ΣΣ
                    ... implicitRules ?!Σ?!Σ
                      ... language
                        ... text
                          ... contained
                            ... extension ExtensionExtension
                            • Elements differ in short: "Additional content defined by implementations" "Extension"
                            • Elements differ in definition: "May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension." "An Extension"
                            ... modifierExtension ?!?!
                              ... identifier ΣΣ
                                ... basedOn ΣΣ
                                  ... partOf ΣΣ
                                    ... status ?!SΣ?!SΣ
                                      ... Slices for category S
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... code SΣSΣ
                                      • Elements differ in short: "Heart Rate" "Type of observation (code / type)"
                                      • Elements differ in definition: "Coded Responses from C-CDA Vital Sign Results." "Describes what was observed. Sometimes this is called the observation "name"."
                                      • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                      • Elements differ in binding.description: "The vital sign codes from the base FHIR and US Core Vital Signs." "Codes identifying names of simple observations."
                                      ... subject SΣSΣI
                                        ... focus ΣΣI
                                          ... encounter ΣΣ
                                            ... effective[x] SΣIΣ
                                            • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                            • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... issued ΣΣ
                                              ... performer ΣSΣ
                                              • Elements differ in definition for mustSupport: "false" "true"
                                              ... Slices for value[x] SΣIΣI
                                              • Elements differ in short: "Vital Signs Value" "Actual result"
                                              • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type." "The information determined as a result of making the observation, if the information has a simple value."
                                              • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                              • Elements differ in definition for mustSupport: "true" "false"
                                              ... dataAbsentReason SISI
                                              • Elements differ in comments: "Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values." "Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values."
                                              ... interpretation
                                                ... note
                                                  ... bodySite
                                                    ... method S
                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                    ... specimen
                                                      ... device
                                                        ... referenceRange II
                                                          .... id
                                                            .... extension ExtensionExtension
                                                              .... modifierExtension ?!Σ?!Σ
                                                                .... low II
                                                                  .... high II
                                                                    .... type
                                                                      .... appliesTo
                                                                        .... age
                                                                          .... text
                                                                            ... hasMember ΣΣ
                                                                            • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                            • Elements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."
                                                                            • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                            ... derivedFrom ΣSΣ
                                                                            • Elements differ in definition for mustSupport: "false" "true"
                                                                            ... component SΣISΣI
                                                                            • Elements differ in short: "Component observations" "Component results"
                                                                            • Elements differ in definition: "Used when reporting component observation such as systolic and diastolic blood pressure." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes."
                                                                            • Elements differ in requirements: "Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation." "Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable)."
                                                                            .... id
                                                                              .... extension ExtensionExtension
                                                                                .... modifierExtension ?!Σ?!Σ
                                                                                  .... code SΣΣ
                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                  • Elements differ in binding.description: "The vital sign codes from the base FHIR and US Core Vital Signs." "Codes identifying names of simple observations."
                                                                                  .... value[x] SΣIΣ
                                                                                  • Elements differ in short: "Vital Sign Component Value" "Actual component result"
                                                                                  • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                  • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                  .... dataAbsentReason SII
                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                  .... interpretation
                                                                                    .... referenceRange

                                                                                      doco Documentation for this format