Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-head-circumference' vs 'http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationRace' |
Error | StructureDefinition.version | Values for version differ: '4.1.0' vs '1.1.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreHeadCircumferenceProfile' vs 'SDOHCCObservationRace' |
Information | StructureDefinition.title | Values for title differ: 'US Core Head Circumference Profile' vs 'SDOHCC Observation Race' |
Information | StructureDefinition.status | Values for status differ: 'active' vs 'draft' |
Information | StructureDefinition.date | Values for date differ: '2020-11-18' vs '2021-12-07T14:30:02+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International - Patient Care WG' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'US Core Head Circumference Profile'
'Race observation' |
Warning | Observation | Elements differ in definition:
'Defines constraints on Observation to represent head circumference observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
'For observations about the race of an individual.' |
Warning | Observation.extension | Elements differ in short:
'Additional content defined by implementations'
'Extension' |
Warning | Observation.extension | Elements differ in definition:
'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.'
'An Extension' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Head Circumference'
'Type of observation (code / type)' |
Warning | Observation.code | Elements differ in definition:
'Coded Responses from C-CDA Vital Sign Results.'
'Describes what was observed. Sometimes this is called the observation 'name'.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Warning | Observation.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinically relevant time/time-period for observation' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Error | Observation.effective[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.performer | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs Value'
'Actual result' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.dataAbsentReason | Elements differ in comments:
'Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be 'detected', 'not detected', 'inconclusive', or 'specimen unsatisfactory'.
The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code 'error' could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.'
'Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value.
The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values.' |
Error | Observation.method | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Related resource that belongs to the Observation group' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Error | Observation.derivedFrom | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.component | Elements differ in short:
'Component observations'
'Component results' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting component observation such as systolic and diastolic blood pressure.'
'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes.' |
Warning | Observation.component | Elements differ in requirements:
'Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.'
'Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable).' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Component Value'
'Actual component result' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |