Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus' vs 'http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-nhcs' |
Error | StructureDefinition.version | Values for version differ: '4.0.0' vs '1.0.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreSmokingStatusProfile' vs 'NarrativeHistoryOfCognitiveStatus' |
Information | StructureDefinition.title | Values for title differ: 'US Core Smoking Status Observation Profile' vs 'PACIO Narrative History of Cognitive Status' |
Information | StructureDefinition.date | Values for date differ: '2019-05-21T00:00:00+00:00' vs '2021-11-03T21:45:55+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 Patient Care Work Group' |
Warning | Observation | Elements differ in definition:
'The US Core Smoking Status Observation Profile is based upon the core FHIR Observation Resource and created to meet the USCDI Data Set 'Smoking status' requirements.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Warning | Observation.extension | Elements differ in short:
'Additional content defined by implementations'
'Extension' |
Warning | Observation.extension | Elements differ in definition:
'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.'
'An Extension' |
Warning | Observation.basedOn | Elements differ in short:
'Fulfills plan, proposal or order'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.partOf | Elements differ in short:
'Part of referenced event'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.status | Elements differ in short:
'registered | preliminary | final | amended +'
'Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.' |
Error | Observation.status | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Smoking Status'
'Type of observation (code / type)' |
Error | Observation.code | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.subject | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.focus | Elements differ in short:
'What the observation is about, when it is not about the subject of record'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.issued | Elements differ in short:
'Date/Time this version was made available'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.performer | Elements differ in short:
'Who is responsible for the observation'
'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.' |
Warning | Observation.value[x] | Elements differ in short:
'Actual result'
'Unstructured summary of cognitive status observation for the patient. (Strongly encouraged until more structured method is established)' |
Warning | Observation.value[x] | Elements differ in definition:
'The information determined as a result of making the observation, if the information has a simple value.'
'Unstructured summary of cognitive status observation for the patient. (Strongly encouraged until more structured method is established)' |
Warning | Observation.interpretation | Elements differ in short:
'High, low, normal, etc.'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.bodySite | Elements differ in short:
'Observed body part'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.method | Elements differ in short:
'How it was done'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.specimen | Elements differ in short:
'Specimen used for this observation'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.device | Elements differ in short:
'(Measurement) Device'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.referenceRange | Elements differ in short:
'Provides guide for interpretation'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.hasMember | Elements differ in short:
'Related resource that belongs to the Observation group'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.derivedFrom | Elements differ in short:
'Related measurements the observation is made from'
'Currently not used in PriorLevelOfCognitiveFunction.' |
Warning | Observation.component | Elements differ in short:
'Component results'
'Currently not used in PriorLevelOfCognitiveFunction.' |