Profile Comparison between http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs vs http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs

Left:PACIO Cognitive Status (http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs)
Right:PACIO Cognitive Status (http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs)

Messages

ErrorStructureDefinition.versionValues for version differ: '0.1.0' vs '1.0.0'
InformationStructureDefinition.dateValues for date differ: '2020-10-17T01:12:51+00:00' vs '2021-11-03T21:45:55+00:00'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in definition: 'This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements.' 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservation.statusElements differ in short: 'Should have the value 'final' to indicate the observation is complete.' 'Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.categoryElements differ in short: 'Classification of type of observation' 'A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'For a Post-Acute Care Assessment, should include a LOINC code and text for the question.' 'For a Post-Acute Care Assessment, should include a LOINC code and text for the question or concept name.'
WarningObservation.codeElements differ in definition: 'The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
ErrorObservation.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.subjectElements differ in short: 'Should only reference a Patient resource' 'Should only reference a Patient resource.'
ErrorObservation.subjectElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.effective[x]Elements differ in definition: 'For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.performerElements differ in short: 'The person who performed the assessment. May also be used to provide the practitioner role and organization.' 'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.'
WarningObservation.value[x]Elements differ in short: 'Result Value' 'Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension.'
WarningObservation.value[x]Elements differ in definition: 'The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification.' 'The information determined as a result of making the observation, if the information has a simple value.'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.derivedFromElements differ in short: 'Related measurements the observation is made from' 'Should point back to the SDC QuestionnaireResponse that this resource is derived from.'
ErrorObservation.derivedFromElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.derivedFromType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]])
WarningObservation.componentElements differ in short: 'If used, the answers for the associated questions (for the purpose of grouping answers under a heading and displaying side-by-side columns)' 'Currently not used in CognitiveStatus.'
WarningObservation.component.codeElements differ in short: 'If used, the LOINC code or text of the column header (for the purpose of grouping answers under a heading and displaying side-by-side columns).' 'Type of component observation (code / type)'
WarningObservation.component.value[x]Elements differ in short: 'The code and text for the answer to the (associated) question.' 'Actual component result'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-labhttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyright
      .date2020-10-17T01:12:51+00:002021-11-03T21:45:55+00:00
      • Values Differ
      .descriptionAn exchange of cognitive status data for a patient.An exchange of cognitive status observation for a patient. This profile is used for exchanging a single observation data generally included in a set of observation data collected through the use of a structured resource (e.g. assessment tool, instrument, or screen).
      • Values Differ
      .experimental
        .fhirVersion4.0.1
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .kindresource
                .nameCognitiveStatus
                  .publisherHL7 Patient Care Work Group
                    .purpose
                      .statusactive
                        .titlePACIO Cognitive Status
                          .typeObservation
                            .urlhttp://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs
                              .version0.1.01.0.0
                              • Values Differ

                              Structure

                              NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                              .. Observation II
                              • Elements differ in definition: "This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements." "Measurements and simple assertions made about a patient, device or other subject."
                              ... id ΣΣ
                                ... meta ΣΣ
                                  ... implicitRules ?!Σ?!Σ
                                    ... language
                                      ... text
                                        ... contained
                                          ... Slices for extension ExtensionExtension
                                            ... modifierExtension ?!?!
                                              ... identifier ΣΣ
                                                ... basedOn ΣΣ
                                                  ... partOf ΣΣ
                                                    ... status ?!SΣ?!Σ
                                                    • Elements differ in short: "Should have the value 'final' to indicate the observation is complete." "Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used."
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... Slices for category S
                                                    • Elements differ in short: "Classification of type of observation" "A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code."
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... code SΣΣ
                                                    • Elements differ in short: "For a Post-Acute Care Assessment, should include a LOINC code and text for the question." "For a Post-Acute Care Assessment, should include a LOINC code and text for the question or concept name."
                                                    • Elements differ in definition: "The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."
                                                    • Elements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... subject SΣΣ
                                                    • Elements differ in short: "Should only reference a Patient resource" "Should only reference a Patient resource."
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... focus ΣΣ
                                                      ... encounter ΣΣ
                                                        ... effective[x] SΣIΣ
                                                        • Elements differ in definition: "For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                                        • Elements differ in definition for mustSupport: "true" "false"
                                                        ... issued ΣΣ
                                                          ... performer ΣΣ
                                                          • Elements differ in short: "The person who performed the assessment. May also be used to provide the practitioner role and organization." "The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization."
                                                          ... value[x] SΣIΣI
                                                          • Elements differ in short: "Result Value" "Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension."
                                                          • Elements differ in definition: "The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification." "The information determined as a result of making the observation, if the information has a simple value."
                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                          ... dataAbsentReason SII
                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                          ... interpretation
                                                            ... note
                                                              ... bodySite
                                                                ... method
                                                                  ... specimen
                                                                    ... device
                                                                      ... referenceRange II
                                                                        .... id
                                                                          .... extension ExtensionExtension
                                                                            .... modifierExtension ?!Σ?!Σ
                                                                              .... low II
                                                                                .... high II
                                                                                  .... type
                                                                                    .... appliesTo
                                                                                      .... age
                                                                                        .... text
                                                                                          ... hasMember ΣΣ
                                                                                            ... derivedFrom ΣSΣ
                                                                                            • Elements differ in short: "Related measurements the observation is made from" "Should point back to the SDC QuestionnaireResponse that this resource is derived from."
                                                                                            • Elements differ in definition for mustSupport: "false" "true"
                                                                                            • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]])
                                                                                            ... component ΣΣ
                                                                                            • Elements differ in short: "If used, the answers for the associated questions (for the purpose of grouping answers under a heading and displaying side-by-side columns)" "Currently not used in CognitiveStatus."
                                                                                            .... id
                                                                                              .... extension ExtensionExtension
                                                                                                .... modifierExtension ?!Σ?!Σ
                                                                                                  .... code ΣΣ
                                                                                                  • Elements differ in short: "If used, the LOINC code or text of the column header (for the purpose of grouping answers under a heading and displaying side-by-side columns)." "Type of component observation (code / type)"
                                                                                                  .... value[x] ΣΣ
                                                                                                  • Elements differ in short: "The code and text for the answer to the (associated) question." "Actual component result"
                                                                                                  .... dataAbsentReason II
                                                                                                    .... interpretation
                                                                                                      .... referenceRange

                                                                                                        doco Documentation for this format