Profile Comparison between http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs-dev vs http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs-dev

Left:Use of Device (http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs-dev)
Right:Use of Device (http://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs-dev)

Messages

ErrorStructureDefinition.versionValues for version differ: '0.1.0' vs '1.0.0'
InformationStructureDefinition.dateValues for date differ: '2020-10-17T01:12:51+00:00' vs '2021-11-03T21:45:55+00:00'
WarningDeviceUseStatement.bodySiteElements differ in requirements: 'Knowing where the device is targeted is important for tracking if multiple sites are possible. If more information than just a code is required, use the extension [http://hl7.org/fhir/StructureDefinition/bodySite].' 'Knowing where the device is targeted is important for tracking if multiple sites are possible. If more information than just a code is required, use the extension http://hl7.org/fhir/R4/extension-bodysite.'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/DeviceUseStatement
      .copyright
        .date2020-10-17T01:12:51+00:002021-11-03T21:45:55+00:00
        • Values Differ
        .descriptionA device used by a Patient during a cognitive status assessment.A record of an assistive device--e.g. eyeglasses or hearing aid, being used by a patient during a cognitive status assessment. This profile based on the DeviceUseStatement resource provides a way to include information about device usage during an assessment.
        • Values Differ
        .experimental
          .fhirVersion4.0.1
            .jurisdiction
              ..jurisdiction[0]urn:iso:std:iso:3166#US
                .kindresource
                  .nameUseOfDevice
                    .publisherHL7 Patient Care Work Group
                      .purpose
                        .statusactive
                          .titleUse of Device
                            .typeDeviceUseStatement
                              .urlhttp://hl7.org/fhir/us/pacio-cs/StructureDefinition/pacio-cs-dev
                                .version0.1.01.0.0
                                • Values Differ

                                Structure

                                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                                .. DeviceUseStatement
                                  ... id ΣΣ
                                    ... meta ΣΣ
                                      ... implicitRules ?!Σ?!Σ
                                        ... text
                                          ... contained
                                            ... extension ExtensionExtension
                                              ... modifierExtension ?!?!
                                                ... identifier ΣΣ
                                                  ... basedOn ΣΣ
                                                    ... status ?!Σ?!Σ
                                                      ... subject ΣΣ
                                                        ... derivedFrom ΣΣ
                                                          ... timing[x] ΣΣ
                                                            ... recordedOn ΣΣ
                                                              ... source ΣΣ
                                                                ... device ΣΣ
                                                                  ... reasonCode ΣΣ
                                                                    ... reasonReference ΣΣ
                                                                      ... bodySite ΣΣ
                                                                      • Elements differ in requirements: "Knowing where the device is targeted is important for tracking if multiple sites are possible. If more information than just a code is required, use the extension [http://hl7.org/fhir/StructureDefinition/bodySite]." "Knowing where the device is targeted is important for tracking if multiple sites are possible. If more information than just a code is required, use the extension http://hl7.org/fhir/R4/extension-bodysite."
                                                                      ... note

                                                                        doco Documentation for this format